Sitemap
All pages of FireAlarmPracticeTest.com at a glance.
NICET Fire Alarm Systems Level I
- Home page
- All 299 questions with answers
- Questions about Installation (Peripherals, Cabling, Job Site Safety)
- Questions about Maintenance (Periodic Testing, Repair and Replacement)
- Questions about Submittal Preparation and System Layout (Technical Documents)
NICET Fire Alarm Systems Level II
- NICET Fire Alarm Systems Level II: overview
- All 344 questions with answers
- Questions about Installation
- Questions about Maintenance
- Questions about Submittal Preparation and System Layout
- Questions about Management and Supervision
NICET Fire Alarm Systems Level III
- NICET Fire Alarm Systems Level III: overview
- All 297 questions with answers
- Questions about Installation
- Questions about Maintenance
- Questions about Submittal Preparation and System Layout
- Questions about Management and Supervision
NICET Fire Alarm Systems Level IV
- NICET Fire Alarm Systems Level IV: overview
- All 243 questions with answers
- Questions about Installation, Planning and Maintenance Management
- Questions about Submittals, Shop Drawings and Records
- Questions about Complex Notification and Emergency Communication Systems
- Questions about Complex Detection, Integrated and Special Systems
Texas Fire Alarm License Exam
- Texas Fire Alarm License Exam: overview
- All 172 questions with answers
- Questions about Texas Fire Alarm Law and Rules
- Questions about Texas Technician Technical Knowledge (NFPA 72-2019)
Ohio Fire Alarm Certification Exam
- Ohio Fire Alarm Certification Exam: overview
- All 183 questions with answers
- Questions about Ohio Law, Certification and Fire Code
- Questions about Fundamentals, Definitions and Documentation
- Questions about Circuits, Power Supplies and Control Units
- Questions about Initiating Devices
- Questions about Notification Appliances
- Questions about Inspection, Testing and Maintenance
- Questions about Supervising Stations, Signaling and Household Warning
Oklahoma Fire Alarm Technician Exam
- Oklahoma Fire Alarm Technician Exam: overview
- All 153 questions with answers
- Questions about Oklahoma Alarm Act and ODOL Rules
- Questions about Basic Electronics and Calculations
- Questions about System Layout and NFPA 72 Requirements
- Questions about Installation, Wiring and Pathways
- Questions about Inspection, Testing and Service
- Questions about Job Site Safety
Blog
- All articles
- Fire Alarm Battery Calculation: Worked Example
- How to Get a Fire Alarm License in Texas (2026)
- How to Get NICET Fire Alarm Level I in 2026
- NICET Fire Alarm Certification Statistics 2026
- NICET Fire Alarm Level II: Requirements and Exam
- NICET Fire Alarm Level III and IV Requirements
- Ohio and Oklahoma Fire Alarm License Guide (2026)
Legal
All questions individually: NICET Fire Alarm Systems Level I
Installation (Peripherals, Cabling, Job Site Safety)
- 1001A spot-type smoke detector has to be mounted on a sidewall instead of the ceiling. Where must the top of the detector be located?
- 1002A spot-type heat detector is being mounted on a smooth ceiling. What is the minimum distance from the sidewall?
- 1003A heat detector must be mounted on a sidewall. Which mounting position meets NFPA 72?
- 1004On a smooth, flat ceiling with no performance-based design, what nominal spacing is used for spot-type smoke detectors?
- 1005Smoke detectors on a smooth ceiling are laid out at a 30 ft nominal spacing. Every point on the ceiling must be within what distance of a detector?
- 1006A heat detector has a listed spacing of 50 ft and is installed on a smooth 9 ft ceiling. What is the maximum distance from any wall to the nearest detector, measured at right angles?
- 1007A heat detector listed for 50 ft spacing is installed on a smooth 15 ft high ceiling. Using the NFPA 72 high ceiling reduction factor of 0.77 for 14 to 16 ft, what is the adjusted spacing?
- 1008The highest expected ceiling temperature in a mechanical room is 120 F. What is the lowest fixed-temperature heat detector rating that may be used?
- 1009A fixed-temperature heat detector is rated 194 F. In which NFPA 72 temperature classification does it fall?
- 1010What color marking identifies a heat detector in the intermediate temperature classification?
- 1011The general contractor asks you to install the smoke detectors while drywall sanding is still going on, and nobody has required detection for protection during construction. What should you do?
- 1012Smoke detectors were installed early to protect a building during construction. What must happen to them before the system is accepted?
- 1013After installing a new smoke detector you notice the plastic dust cover is still on it. When must the cover come off?
- 1014Under which ambient condition may a spot-type smoke detector NOT be installed unless it is specifically listed for that condition?
- 1015A smoke detector is planned for an unheated garage where winter temperatures fall to 20 F. What is the correct approach?
- 1016When mounting a duct smoke detector housing, how must the sampling tube be installed?
- 1017An owner wants to save money by counting the duct smoke detectors as the smoke detection for the open office areas. Is that acceptable?
- 1018At what height must the operable part of a manual fire alarm box be mounted?
- 1019A manual fire alarm box is required at an exit door. Within what distance of the exit doorway opening must it be located?
- 1020On one floor of a building, what is the maximum travel distance from any point to the nearest manual fire alarm box?
- 1021A tenant wants to hide a manual fire alarm box behind a decorative curtain. What does NFPA 72 require?
- 1022A wall-mounted visible notification appliance (strobe) is being hung in a room with a 10 ft ceiling. Where must its lens be?
- 1023A room has a ceiling only 84 in. high, so a wall strobe cannot meet the normal 80 to 96 in. range. Where may it be mounted?
- 1024A wall-mounted horn (audible only) is installed in a room with a 12 ft ceiling. Where must the top of the horn be?
- 1025You are mounting a combination horn/strobe on a wall. Which mounting rule controls its height?
- 1026The drawings show ceiling-mounted strobes, but the installer looks up the candela rating in the wall-mounted spacing table. What is wrong?
- 1027A 40 ft x 40 ft room will be covered by one wall-mounted strobe. Using the NFPA 72 room spacing table, what is the minimum effective intensity?
- 1028A single wall-mounted strobe will cover a 20 ft x 20 ft office. What is the minimum effective intensity from the room spacing table?
- 1029Strobes are being installed in a corridor 10 ft wide and 150 ft long. Which layout meets the corridor rule of the 2022 edition?
- 1030What flash rate must a visible notification appliance used for fire alarm have?
- 1031When must strobes within a field of view be synchronized?
- 1032What light color is required for public mode visible alarm appliances that signal a fire alarm?
- 1033Why must polarity be observed when terminating a horn/strobe on a notification appliance circuit?
- 1034On a conventional Class B initiating device circuit, how should the installer connect the wires at a smoke detector base?
- 1035Where is the end-of-line resistor normally installed on a conventional Class B initiating device circuit?
- 1036Why is a T-tap not allowed on a conventional Class B initiating device circuit that uses an end-of-line resistor?
- 1037What does a Class A pathway provide that a Class B pathway does not?
- 1038A single open occurs halfway along a Class B initiating device circuit. What happens?
- 1039When installing a Class A circuit, how should the outgoing and return conductors be run?
- 1040Which pathway class keeps operating through a single open, a single ground fault, or a single short circuit?
- 1041A single ground fault occurs on a supervised initiating device circuit. What should the panel do?
- 1042Within how many seconds must a single open or single ground fault on monitored installation conductors be indicated?
- 1043On a conventional two-wire smoke detector zone, what is the purpose of the detector base wiring when the head is removed?
- 1044Four-wire smoke detectors get their operating power from a separate power circuit. What must be installed to supervise that power?
- 1045A two-wire smoke detector from a different manufacturer is offered as a replacement on an existing conventional zone. What must be confirmed?
- 1046When installing a fire alarm device, which instructions must be followed in addition to the code?
- 1047Two addressable smoke detectors on the same signaling line circuit were accidentally set to the same address. What is the likely result?
- 1048When installing a vane-type waterflow switch on a sprinkler pipe, what must the installer check?
- 1049A waterflow switch has an adjustable retard. Within what time after water flow begins must the switch activate?
- 1050When must a valve supervisory (tamper) switch send its off-normal signal?
- 1051A ceiling is peaked, with slopes rising to a ridge. Where is the first row of spot-type smoke detectors placed?
- 1052Which article of the National Electrical Code covers fire alarm system wiring?
- 1053A power-limited fire alarm cable will be run through a ceiling space used for environmental air (a plenum). Which cable type is required?
- 1054A power-limited fire alarm cable runs vertically through a shaft from floor to floor. Which cable type is the minimum rating suitable for this riser?
- 1055Your shop has no FPLR on the truck. Which cable may be substituted for FPLR in a riser application?
- 1056Which cable may be used in place of FPLP in a plenum?
- 1057What does the letter group NPLF on a fire alarm cable jacket indicate?
- 1058How does the NEC require fire alarm circuits to be identified?
- 1059Where must equipment supplying power-limited fire alarm circuits be marked as such?
- 1060May a power-limited fire alarm cable be pulled into the same raceway as 120 V lighting conductors?
- 1061An exposed PLFA cable is run near open power and lighting conductors. What minimum separation does the NEC require in other applications?
- 1062How must exposed fire alarm cables be installed according to the NEC?
- 1063May fire alarm cables be supported by the hanger wires of a suspended ceiling grid?
- 1064A fire alarm cable passes through a fire-rated wall. What must be done at the penetration?
- 1065During a renovation you find old fire alarm cable that is no longer connected and not tagged for future use. What does the NEC require?
- 1066Cable is installed through bored holes in wood studs. If the hole is closer than the required distance to the face of the stud, what protection is required?
- 1067What is the minimum size for single conductors used in non-power-limited fire alarm circuits?
- 1068A fire alarm cable must be installed in an underground conduit between two buildings. What must the cable be rated for?
- 1069The branch circuit that supplies a fire alarm control unit must be which of the following?
- 1070How must the disconnecting means of the fire alarm branch circuit be marked?
- 1071Where must the location of the fire alarm branch circuit overcurrent device be recorded?
- 1072May the branch circuit for a fire alarm control unit be protected by a ground-fault circuit interrupter (GFCI)?
- 1073More than two conductors are pulled into a conduit. What maximum percentage of the conduit cross section may they fill?
- 1074Between pull points, what is the maximum total of bends allowed in an EMT run?
- 1075How must EMT be supported near a junction box?
- 1076Cable ties used to bundle fire alarm cables in a plenum must have which property?
- 1077Where must splices in fire alarm wiring be made?
- 1078A shielded cable is used for an addressable loop. Where is the drain wire usually connected?
- 1079When pulling fire alarm cable, what should the installer watch to avoid damaging it?
- 1080In the NEC color code, which insulation color identifies an equipment grounding conductor?
- 1081Which cable type is used where a fire alarm circuit must survive fire for a rated time without extra protection?
- 1082What does pathway survivability Level 0 mean in NFPA 72?
- 1083An installer strips too much insulation, leaving bare copper outside a detector terminal. What is the risk?
- 1084A 24 V DC circuit has a 2,400 ohm resistance. What current flows?
- 1085A strobe draws 0.115 A at 24 V. How much power does it use?
- 1086Three resistors of 100 ohm, 220 ohm and 680 ohm are connected in series. What is the total resistance?
- 1087Two 10,000 ohm resistors are connected in parallel. What is the combined resistance?
- 1088A notification appliance circuit carries 1.5 A over a 300 ft one-way run of 14 AWG solid copper with 3.07 ohm per 1,000 ft. What is the voltage drop?
- 1089A 24 V NAC has a calculated voltage drop of 2.76 V. What percentage of the source voltage is that?
- 1090Using the formula VD = 2 x K x I x L / CM with K = 12.9, find the voltage drop for 1.2 A over 250 ft one way on 14 AWG (4,110 circular mils).
- 1091What is the circular mil area of a 14 AWG conductor?
- 1092Which conductor has the largest cross section?
- 1093A NAC power supply circuit is rated 2.5 A. Each strobe draws 0.12 A. How many strobes can be connected without exceeding the rating?
- 1094Two 12 V, 7 Ah batteries are connected in series for a 24 V panel. What is the result?
- 1095A 24 V NAC can tolerate a maximum voltage drop of 3 V. Total load is 2 A on 14 AWG wire with 3.07 ohm per 1,000 ft. What is the maximum one-way circuit length?
- 1096A 24 V circuit carries 0.5 A. What resistance does the load have?
- 1097What type of power does a typical fire alarm control unit use for its primary supply and for its notification circuits?
- 1098You set up an extension ladder to reach a mezzanine landing. How far must the side rails extend above the upper landing surface?
- 1099At what angle should a non-self-supporting extension ladder be set up?
- 1100An extension ladder has a working length of 20 ft to the top support point. How far from the wall should the base be?
- 1101You need to reach a ceiling detector from a stepladder. Which practice is NOT allowed?
- 1102You must work near exposed energized electrical equipment from a ladder. What type of ladder is required?
- 1103A self-supporting portable ladder must be able to support at least how many times its maximum intended load?
- 1104You find a ladder with a cracked side rail on the job. What must be done?
- 1105A ladder must be set up in a busy hallway next to a door. What is the correct precaution?
- 1106How should you climb up or down a ladder?
- 1107Before using a portable ladder on a construction site, who must inspect it for visible defects?
- 1108On a construction site, at what height does OSHA require fall protection for a worker on an unprotected side or edge?
- 1109A technician does service work in an existing occupied building (general industry). At what height does OSHA require fall protection on an unprotected edge?
- 1110At what height does OSHA require fall protection for workers on a supported scaffold?
- 1111You are working from a boom-supported aerial lift to install a beam detector. What fall protection is required?
- 1112What is the top rail height of a standard guardrail system on a construction site?
- 1113What is the purpose of the OSHA lockout/tagout standard?
- 1114Three technicians will work on the same de-energized equipment. How should lockout be handled?
- 1115Who may remove a lockout device under normal conditions?
- 1116How does a tagout device differ from a lockout device?
- 1117Before touching conductors you have de-energized, you test them with a voltage tester. What else must you do?
- 1118You need to replace a power supply board inside a fire alarm control unit. What must be disconnected to make the unit safe?
- 1119On a construction site, which receptacles used by employees require ground-fault circuit interrupter protection?
- 1120You are drilling overhead into a concrete ceiling to mount a device box. What eye protection is required?
- 1121Drilling into concrete creates dust that contains respirable crystalline silica. Which control method is typical under the OSHA silica standard?
- 1122While pulling cable above a ceiling, you find old sprayed-on fireproofing that may contain asbestos. What should you do?
- 1123Where can a worker find the hazards, PPE and first aid measures for a chemical such as firestop sealant?
- 1124What is the OSHA occupational noise action level, at which a hearing conservation program is required?
- 1125Who is responsible for assessing the workplace for hazards that require personal protective equipment?
- 1126When must workers wear protective helmets (hard hats) on a construction site?
- 1127A coworker has received an electric shock and is still touching the energized conductor. What is the first thing to do?
- 1128Unqualified workers and their conductive tools must stay how far from overhead power lines of 50 kV or less?
- 1129When handling and installing lead-acid standby batteries, which hazard is most important to control?
- 1130Cords and tools are left lying across a stairway at the job site. Which OSHA requirement does this violate?
- 1131A power tool's cord has damaged outer insulation with the inner conductors showing. What should you do?
- 1132On the job you are asked to open a 480 V electrical panel to find a circuit for the fire alarm. You are not trained or qualified for that work. What should you do?
- 1133When a ladder is used to access a ceiling device, where should the ladder be placed?
- 1134Speaker wiring for a voice evacuation system is being installed. A speaker is set to the 1 W tap on a 25 V circuit. Why is the tap setting important?
- 1135An installer mounts a smoke detector directly in the airflow of an HVAC supply diffuser. What is the likely problem?
- 1136In a dwelling unit, a smoke alarm is planned right next to a bathroom door. What minimum horizontal distance from a door to a bathroom with a shower or tub is required, where possible?
- 1137In a dwelling unit with a ceiling fan, how far from the tip of the fan blade must a smoke alarm be located, where possible?
- 1138A new ionization smoke alarm without an alarm silencing feature is planned in a home near the kitchen range. What does NFPA 72 say about this location?
- 1139A detector back box must be mounted on a drop ceiling tile. What is the correct method?
- 1140How many conductors may share a device box is determined by which NEC rule?
- 1141An addressable monitor module will supervise a sprinkler tamper switch. What is the module's job?
- 1142Which device is used to let the fire alarm system switch an external load, such as releasing door holders?
- 1143Where must a relay or control module that performs an emergency control function, such as fan shutdown, be located?
- 1144A sprinkler system serves an elevator machine room and the elevator power is shunt tripped on waterflow. Where must the heat detectors for elevator shutdown be located?
- 1145When a technician mounts a smoke detector near a ceiling beam on a ceiling with deep beams, what must be checked before installation?
- 1146Which NFPA 72 pathway class is intended for Ethernet-type networks with redundant equipment paths?
- 1147An installer mounts a monitor module above a ceiling to watch a sprinkler tamper switch. What should be done so it can be found later?
Maintenance (Periodic Testing, Repair and Replacement)
- 2001How often must spot-type smoke detectors receive a functional test?
- 2002When is the first sensitivity test of newly installed smoke detectors required?
- 2003After the first sensitivity test, how often are smoke detector sensitivity tests normally repeated?
- 2004Two consecutive sensitivity tests show a group of smoke detectors stayed within their listed range. What is the maximum interval the tests may then be extended to?
- 2005Which method may NOT be used to measure smoke detector sensitivity?
- 2006What does a proper annual functional test of a spot-type smoke detector have to prove?
- 2007How is a restorable spot-type fixed-temperature heat detector functionally tested?
- 2008Why is a heat test not done on a nonrestorable fixed-temperature heat detector?
- 2009Nonrestorable spot-type fixed-temperature heat detectors have been in service for 15 years. What is required?
- 2010A building has 300 nonrestorable spot-type heat detectors that are 15 years old. The owner chooses lab testing instead of replacement. How many detectors must be sent for testing?
- 2011How often are manual fire alarm boxes functionally tested?
- 2012How often are audible and visible notification appliances functionally tested?
- 2013How often must sprinkler waterflow alarm devices connected to the fire alarm system be tested?
- 2014How often must valve supervisory (tamper) switches be tested?
- 2015A waterflow switch is tested by opening the inspector's test valve. What flow is the test meant to simulate?
- 2016During a tamper switch test you close the valve. When should the supervisory signal clear?
- 2017Before starting a test that will activate initiating devices, who must be notified?
- 2018You have finished testing a building and restored the system. What notification is required at the end?
- 2019Who is responsible for making sure a fire alarm system is inspected, tested and maintained?
- 2020How long must inspection and test records be kept?
- 2022After a new device is installed on an existing system, what testing is required?
- 2023The site-specific software of a control unit was changed. Besides the functions known to be affected, how many other initiating devices must be tested?
- 2024What is the purpose of the 100 percent acceptance test on a new fire alarm system?
- 2025At acceptance testing, how are installation conductors checked for unwanted voltages?
- 2026To measure loop resistance of an initiating device circuit during acceptance testing, what is done at the far end of the circuit?
- 2027A technician checks fire alarm conductors for isolation from ground. What is being looked for?
- 2028You need to megger (insulation resistance test) a new fire alarm circuit. What must be done first?
- 2029When measuring the voltage on a notification appliance circuit with a multimeter, how is the meter connected?
- 2030When measuring current drawn by a strobe circuit with a multimeter, how is the meter connected?
- 2031Why must resistance measurements be made with the circuit de-energized?
- 2032You disconnect a Class B initiating device circuit at the panel and measure across the pair. The meter shows about 4,700 ohm, matching the EOL value. What does this tell you?
- 2033Measured across a disconnected Class B circuit pair, the meter shows OL (over limit). What is the most likely problem?
- 2034Across a disconnected initiating circuit pair, the meter reads close to 0 ohm. What is the most likely problem?
- 2035A panel shows a ground fault. Which technique is commonly used to locate it on a long circuit?
- 2036What sound level meter weighting is used to measure fire alarm audibility?
- 2037At what height above the floor are audibility measurements normally taken?
- 2038The average ambient sound level in a store is 62 dBA. What minimum fire alarm sound level is needed for public mode, if no louder short-term noise is present?
- 2039In a factory, the average ambient is 70 dBA but a machine produces 88 dBA for several minutes at a time. What minimum public mode sound level is needed?
- 2040In a private mode signaling area, such as a nurses station, how far above the average ambient must the signal be?
- 2041In sleeping areas, what minimum sound level is required at the pillow, besides the 15 dB over ambient rule?
- 2042Which audible signal frequency is required for alarm signals that awaken sleeping occupants in sleeping areas where required by NFPA 72?
- 2043What is the maximum sound pressure level allowed for audible fire alarm signals?
- 2044Two horns each produce 80 dBA at a measuring point. What is the combined level at that point?
- 2045A horn measures 90 dBA at 10 ft in a free field. What level would you expect at 20 ft?
- 2046What pattern does the standard evacuation signal (temporal-3) use?
- 2047For a fire alarm system that is not a voice system, what secondary power capacity does NFPA 72 require?
- 2048For an in-building emergency voice/alarm communications system, how long must the batteries run the system in alarm after 24 hours of standby?
- 2049A panel draws 0.25 A in standby and 2.0 A in alarm. Using 24 hours standby, 5 minutes alarm and the 1.25 aging correction factor required by NFPA 72 (2022/2025), what battery capacity is needed?
- 2050A small panel draws 0.150 A in standby and 1.2 A in alarm. Without a safety factor, what is the required battery capacity for 24 hours standby plus 5 minutes alarm?
- 2051How must storage batteries for a fire alarm system be marked?
- 2052During the annual test, a sealed lead-acid battery cannot hold its voltage under load and falls below the manufacturer's limit. What should be done?
- 2053Two batteries in series supply a 24 V panel. One battery fails its test. What is good practice?
- 2054To test the transfer to secondary power, the technician switches off the AC branch circuit. What should happen?
- 2055On a control unit, what is the difference between silencing and resetting?
- 2056What signal type does a fire alarm panel use to report a fault in the system, such as an open circuit?
- 2057A sprinkler control valve has been closed. What type of signal should the panel show?
- 2058During an inspection you see the panel's trouble LED lit and the buzzer was silenced last week. What should you do?
- 2059How often is a visual inspection of control equipment required on a system that is monitored for alarm, supervisory and trouble signals by a supervising station?
- 2060During a visual inspection of smoke detectors, what are you mainly looking for?
- 2061You find a smoke detector that was painted over during a renovation. What is the correct action?
- 2062A new office wall was built and now a smoke detector sits less than a foot from it, inside a small closet created by the wall. What should the technician do?
- 2063A smoke detector head needs to be replaced. Which replacement is acceptable?
- 2064You replace an addressable smoke detector. What must you make sure of before leaving?
- 2065A 15 cd strobe in a room designed for 30 cd has failed. What should it be replaced with?
- 2066A technician finds that a previous service person removed a detector and twisted the wires together to clear a trouble. What should be done?
- 2067A smoke detector reports a maintenance (dirty) alert at the panel. What should be done?
- 2068What is the purpose of drift compensation in a smoke detector?
- 2069An area of a building is having repeated smoke detector nuisance alarms after construction work. What is a likely cause?
- 2070How is a rate-of-rise heat detector correctly tested?
- 2071When testing a duct smoke detector, what else must be checked besides the alarm response to smoke?
- 2072What should happen when a duct smoke detector that controls air movement goes into alarm during a test?
- 2073How is a manual fire alarm box normally tested?
- 2074During the annual test of a horn/strobe circuit, what should the technician verify?
- 2075Sound level measurements of notification appliances are required by NFPA 72 mainly at which tests?
- 2076A sound level meter used for fire alarm audibility tests should meet which instrument class?
- 2077Which tool is used to deliver test aerosol to a ceiling smoke detector from the floor?
- 2078Before testing, a technician puts some zones in test or disable mode. What must be done at the end of the job?
- 2079The panel and its outputs will be tested, but the owner does not want the sprinkler pump or door holders to operate. What is the right approach?
- 2080How often must a digital alarm communicator transmitter (DACT) send an automatic test signal to the supervising station?
- 2081Which maintenance task applies to vented lead-acid batteries but not to sealed VRLA batteries?
- 2082When battery terminals show white or green corrosion, what should the technician do?
- 2083On a two-wire conventional zone, the panel shows a trouble when one detector head is removed. Is this normal?
- 2084A strobe circuit shows a trouble at the panel. Which first check makes the most sense?
- 2085With all strobes on, the voltage at the last strobe of a NAC measures 15.5 V, and the strobes are listed for 16 to 33 V. What is the problem?
- 2086During testing a horn sounds weak and distorted. The other horns on the circuit are normal. What is the most likely cause?
- 2087A waterflow alarm comes in every time the city water pressure surges, without any real flow. What adjustment is most likely needed?
- 2088What is the reason for testing carbon monoxide detectors per their manufacturer's instructions instead of with smoke aerosol?
- 2089A household smoke alarm in an apartment was manufactured 11 years ago. What should be done?
- 2090During acceptance testing of a Class A initiating circuit, how is the redundant path proven?
- 2091How is ground fault supervision of a circuit verified during acceptance testing?
- 2092Within what time must a battery charger be able to recharge fully discharged fire alarm batteries?
- 2093A smoke detector is marked with a listed sensitivity range of 1.0 to 3.5 percent per foot obscuration. The test reads 3.9 percent per foot. What does this mean?
- 2094An addressable panel prints sensitivity readings for every smoke detector. May this be used for the required sensitivity test?
- 2095What qualification does NFPA 72 expect from people who inspect, test and maintain fire alarm systems?
- 2096Which statement about a Level I trainee performing tests is true?
- 2097A device fails its annual test and cannot be fixed the same day. What should the technician do?
- 2098What is the difference between a deficiency and an impairment in NFPA 72 terms?
- 2099Which records must stay with the system for its entire life, rather than only for a test cycle?
- 2100What is positive alarm sequence (PAS)?
- 2101Under positive alarm sequence, how quickly must trained staff acknowledge the alarm at the control unit?
- 2102When a fire alarm system activates door hold-open releases during testing, what should the technician verify?
- 2103An elevator lobby smoke detector is activated during testing. What should the elevators do?
- 2104A projected beam smoke detector needs its annual functional test. Which method is acceptable?
- 2105When cleaning a spot-type smoke detector, what should guide the method?
- 2106What is the main purpose of the panel lamp test function?
- 2107During testing, the panel shows an alarm, but the supervising station reports it received a trouble. What does this indicate?
- 2108A pressure-type waterflow switch is used on a dry pipe sprinkler system. What does it sense?
- 2109On a dry pipe sprinkler system, which condition sends a supervisory signal, not an alarm?
- 2110The ambient sound in a hotel room is 40 dBA. What minimum alarm level is needed at the pillow?
- 2111Which pattern identifies a carbon monoxide alarm signal?
- 2112What should the panel do when a single conventional smoke detector circuit goes into alarm and alarm verification is enabled?
- 2113What does a supervising station do with signals from a protected building?
- 2114After a fire alarm technician finishes a repair to field wiring, what testing is needed?
- 2115Which tool is best for measuring the current drawn by a NAC without opening the circuit?
- 2116A NAC carries 1.8 A in alarm and the voltage at the panel is 24 V. The total wire resistance out and back is 2.0 ohm. What voltage reaches the end of the circuit?
- 2117An initiating device circuit has a 3,900 ohm EOL resistor and 24 V across it. What supervisory current flows in normal standby, ignoring the detectors?
- 2118With all appliances operating, the current on a strobe circuit is measured at 2.9 A. The NAC is rated 2.5 A. What should be done?
- 2119What should the technician check when inspecting a remote annunciator?
- 2120The inspection report must be provided to whom after a test?
- 2121Which information belongs in an inspection and test record?
- 2122A smoke detector in a hallway is about 30 years old. It still passes its functional and sensitivity tests. What is generally true?
- 2123A heat detector of the line type (linear heat cable) is the nonrestorable kind. How is its annual test done?
- 2124During a visual inspection, you find storage stacked within a few inches of a ceiling heat detector. What is the concern?
- 2125Why should a technician wait for the smoke to clear a detector before resetting the panel during a test?
- 2126When a fire alarm system will be out of service for repair, what interim measure might the owner have to provide?
- 2127What is the main reason to notify the supervising station before testing?
- 2128During an annual test, a technician activates a smoke detector, and the panel shows the alarm but no horns sound. Which check comes first?
- 2129How should replacement fuses in a fire alarm panel be chosen?
- 2130What is the normal state of the panel's AC power indicator in standby?
- 2131When inspecting a strobe in a room, the lens is cracked but the strobe still flashes. What should be done?
- 2132Why are batteries disconnected last when powering down a panel for service and connected after AC when powering up, in many manufacturers' instructions?
- 2133A technician must measure the resistance of an initiating circuit. What must be done first?
- 2134Before an insulation resistance (megger) test on field wiring, what must be disconnected?
- 2135After a fire alarm test is finished, which step completes the job on site?
Submittal Preparation and System Layout (Technical Documents)
- 3001A floor plan is drawn at a scale of 1/8 in = 1 ft. On the drawing, the distance between two detectors measures 3.5 in. What is the real distance?
- 3002On a drawing with a scale of 1/4 in = 1 ft, a corridor measures 6 in long. How long is the corridor?
- 3003Where on a set of fire alarm drawings should you look first to find out what a device symbol means?
- 3004Which fire alarm drawing shows the vertical arrangement of panels, risers and circuits floor by floor?
- 3005Which document shows what each input does to each output, for example which detector shuts down which fan?
- 3006On fire alarm drawings, what does the abbreviation SLC stand for?
- 3007A note on a plan says a manual box is mounted at 48 in. AFF. What does AFF mean?
- 3008In the CSI MasterFormat used for construction specifications, where is the fire detection and alarm section found?
- 3009Before installation begins, what normally has to happen with fire alarm shop drawings?
- 3010Which document is completed at the end of a new installation to record the system's details and test results?
- 3011What are record drawings (as-builts)?
- 3012Where must system record documents be stored on site?
- 3013The plans show a smoke detector right in front of an HVAC supply diffuser that was moved in the field. What should a Level I technician do?
- 3014Where would you look to find a strobe's current draw at each candela setting?
- 3015What is the main purpose of the title block on a drawing sheet?
- 3016Two sheets of the same drawing set show different revision letters, B and D. Which should you install from?
- 3017Which symbol type on a fire alarm floor plan most likely shows a wall-mounted horn/strobe?
- 3018Which document should be followed for wiring terminals and settings of a specific device when the plans do not show them?
All questions individually: NICET Fire Alarm Systems Level II
Installation
- 1001Which pathway class includes a redundant path and keeps operating past a single open, but is not required to keep operating past a single short?
- 1002A technician opens one conductor in the middle of a Class B initiating device circuit. What happens to the devices beyond the break?
- 1003Which pathway class is designed to keep operating during a single short circuit on the pathway?
- 1004A door holder circuit releases the doors whenever its pathway fails, and no trouble is annunciated. Which pathway class describes this behavior?
- 1005Which pathway class applies to pathways that are not monitored for integrity at all?
- 1006An IP based link to a remote annunciator is checked only through periodic end to end communication, and loss of that communication is reported as trouble. The individual paths are not monitored. Which class is this?
- 1007Which pathway class was created specifically for modern Ethernet infrastructure serving fire alarm or emergency communication devices?
- 1008On a Class A or Class B pathway, how must a single ground fault be treated?
- 1009For a Class A circuit, why does NFPA 72 require the outgoing and return conductors to be routed separately?
- 1010Under the separation rule for Class A and Class X pathways, what minimum separation applies between outgoing and return pathways run vertically?
- 1011Under the separation rule for Class A and Class X pathways, what minimum separation applies between outgoing and return pathways run horizontally?
- 1012What does pathway survivability Level 0 require?
- 1013A pathway is run in metal raceway in a building fully protected by an NFPA 13 sprinkler system. Which survivability level does this describe?
- 1014Which method meets pathway survivability Level 2?
- 1015What distinguishes survivability Level 3 from Level 2?
- 1016Under NFPA 70 Article 760, what are the three types of listed power-limited fire alarm cable, from most to least fire resistive in application?
- 1017A PLFA cable will be installed in a ceiling space used for environmental air (plenum). Which cable type is suitable without a raceway?
- 1018A PLFA circuit runs vertically through floors in a shaft. Which cable type is the lowest rating suitable for that riser application?
- 1019Which cable may be substituted for FPL in a general purpose PLFA application?
- 1020What minimum separation does NFPA 70 generally require between PLFA conductors and electric light or power conductors when neither is in a raceway or a permitted cable sheath?
- 1021May PLFA conductors and 120 V power conductors share the same raceway?
- 1022Which circuit types may share a cable with PLFA conductors under NFPA 70?
- 1023What does NFPA 70 require for the branch circuit supplying a fire alarm control unit?
- 1024Where must the location of the fire alarm branch circuit disconnecting means be documented?
- 1025NFPA 70 requires fire alarm circuits to be identified at terminal and junction locations. What is the purpose?
- 1026How must exposed fire alarm cables above a suspended ceiling be supported under NFPA 70?
- 1027What must be done with the accessible portion of abandoned fire alarm cable?
- 1028Cable ties used to secure fire alarm cables in a plenum space must have what property?
- 1029What is the minimum conductor size permitted for NPLFA circuits?
- 1030What is the maximum overcurrent protection for 18 AWG NPLFA conductors?
- 1031What is the minimum insulation voltage rating for NPLFA conductors?
- 1032Which equipment marking does NFPA 70 require where a power supply provides PLFA circuits?
- 1033A contractor wants to run PLFA cable in an elevator hoistway. What does NFPA 70 require?
- 1034What NEC rule governs fire alarm cable penetrations through fire resistance rated walls?
- 1035Which NFPA 70 article primarily covers fire alarm system wiring?
- 1036PLFA conductors and NPLFA conductors must terminate in the same control unit enclosure. What does NFPA 70 require?
- 1037Which suffix identifies a cable that has been tested to keep circuit integrity during a fire for a specified rating, such as 2 hours?
- 1038What NFPA 70 requirement applies to fire alarm circuits that are installed behind panels designed to allow access, such as lift-out ceiling tiles?
- 1039Before installing devices on a new project, what is the first document a Level II technician should compare against field conditions to build a work plan?
- 1040During rough-in, the technician finds that a duct now sits where a smoke detector is shown on the approved drawing. What is the correct action?
- 1041Which item must be installed so that the fire alarm system wiring does not degrade over time and terminations stay reliable?
- 1042What does NFPA 72 require for the primary power source of a fire alarm system?
- 1043Which mechanical protection is required for the fire alarm branch circuit disconnecting means?
- 1044Where can conductors of a Class A NAC be allowed to share a single conduit for the outgoing and return run without violating the separation rule?
- 1045Where must a smoke detector used for elevator recall be located?
- 1046Which kind of detector is normally used to initiate elevator power shutdown (shunt trip) before sprinklers discharge in the machine room?
- 1047For elevator shunt trip, how close must the heat detector be to each sprinkler head it protects?
- 1048Which signal should a sprinkler waterflow switch with retard delay produce, and what is the maximum delay allowed before the alarm is initiated?
- 1049What is the nominal spacing for spot-type smoke detectors on a smooth ceiling when no other spacing is specified?
- 1050Using the 0.7S rule with a 30 ft nominal spacing, every point on a smooth ceiling must be within what distance of a smoke detector?
- 1051With smooth ceiling spacing of 30 ft, what is the maximum distance from a wall to the nearest row of spot smoke detectors?
- 1052A spot smoke detector is to be mounted on a sidewall instead of the ceiling. Where must its top edge be?
- 1053What minimum distance should a spot smoke detector be from a forced air supply diffuser?
- 1054On a peaked ceiling, where must the first row of smoke detectors be installed?
- 1055How is spacing determined for spot-type heat detectors?
- 1056A heat detector listed for 50 ft spacing will be installed on a smooth ceiling 15 ft high. The reduction factor for a ceiling height above 14 ft up to 16 ft is 0.77. What is the adjusted spacing?
- 1057A heat detector with a listed spacing of 30 ft will be installed on a 12.5 ft high ceiling. The multiplier above 12 ft up to 14 ft is 0.84. What spacing must be used?
- 1058Where should a sidewall mounted spot heat detector be located?
- 1059On a ceiling with solid joists, how is heat detector spacing adjusted in the direction perpendicular to the joists?
- 1060What governs the spacing and mounting of projected beam smoke detectors?
- 1061Why must projected beam smoke detectors be mounted on stable surfaces?
- 1062Can a duct smoke detector be used in place of open area smoke detection?
- 1063What must be verified when installing a duct smoke detector with sampling tubes?
- 1064Where is a duct smoke detector placed on the supply side of an air handling system under NFPA 90A?
- 1065What is the mounting height range for the operable part of a manual fire alarm box?
- 1066Where must manual fire alarm boxes be located relative to exit doorways?
- 1067What is the maximum travel distance to the nearest manual fire alarm box?
- 1068A grouped opening of exit doors is 60 ft wide. Where are manual fire alarm boxes required?
- 1069What is the required mounting height for wall mounted visible notification appliances?
- 1070What range of flash rate is permitted for visible notification appliances?
- 1071When more than two visible appliances are in any field of view, what is required?
- 1072What minimum effective intensity must a visible appliance have in a sleeping area when the lens is less than 24 in. below the ceiling?
- 1073In a sleeping room, a visible appliance must be within what horizontal distance of the pillow?
- 1074A ceiling mounted strobe is to cover a square room on a 10 ft ceiling. Why can't the wall mounted candela table be used for it?
- 1075Where should a wall mounted audible notification appliance be installed?
- 1076In public mode, an audible signal must exceed the average ambient sound level by at least how much?
- 1077In private mode (for example, a staff only area), an audible signal must exceed the average ambient sound by at least how much?
- 1078At what height above the floor are audible notification levels measured for compliance?
- 1079What audible signal frequency is required to awaken occupants in sleeping areas?
- 1080In sleeping areas, which audible level is required at the pillow?
- 1081What is the maximum sound pressure level a fire alarm audible signal may produce?
- 1082What is the purpose of system commissioning before the acceptance test?
- 1083During an initial acceptance test, which devices must be tested?
- 1084Before connecting field wiring to the control unit, which test checks for unintended grounds and stray voltage on new circuits?
- 1085What instrument is used to measure insulation resistance of new fire alarm conductors to ground?
- 1086Where must spot smoke detectors be installed relative to a ceiling fan blade?
- 1087A smoke detector is planned in a room where the ambient temperature can reach 120 F. What must the technician verify?
- 1088Why should smoke detectors generally not be installed until construction cleanup is complete?
- 1089Which detector type should be chosen for an area where smoldering fires are expected to produce large, visible smoke particles?
- 1090What wiring method is used to connect a fire alarm system to a sprinkler valve tamper switch?
- 1091A valve supervisory switch must initiate a signal within what amount of valve movement?
- 1092A combination system shares a control unit for fire alarm and security functions. What must the installer make sure of?
- 1093What is the purpose of an end of line resistor on a conventional Class B initiating device circuit?
- 1094Where must the end of line resistor of a Class B circuit be installed?
- 1095When wiring to an initiating device, why must the circuit conductor be broken at each terminal rather than looped (T-tapped) on a conventional Class B circuit?
- 1096Which type of short circuit isolator placement allows a Class X SLC to keep operating after a single short?
- 1097Which records must be completed for a new system and given to the owner after acceptance?
- 1098In a corridor not more than 20 ft wide, how far apart may visible appliances be spaced under the corridor rule of NFPA 72 (2022)?
- 1099A wall mounted visible appliance must cover a 20 ft by 20 ft room by itself. What minimum effective intensity does the wall mounted room table require?
- 1100A 40 ft by 40 ft room will be covered by one wall mounted strobe. What minimum effective intensity does the wall mounted room table require?
- 1101Which control function is commonly wired from a fire alarm relay to release magnetically held smoke doors?
- 1102Where must the relay or control module that operates an emergency control function be located?
- 1103How are HVAC fan shutdown circuits typically installed when they are not monitored for integrity?
- 1104What must happen to the fire alarm system when an emergency control function interface relay fails?
- 1105Which interface must be provided so that elevators are not recalled to a floor where the lobby detector is in alarm?
- 1106What should a technician do before connecting the fire alarm system to the supervising station during installation?
- 1107Which of these devices is used to check that a wireless (low power radio) initiating device will communicate reliably before final installation?
- 1108How long may a low power radio (wireless) initiating device take to report an alarm signal to the control unit?
- 1109A technician installs a heat detector in an attic where temperatures reach 170 F. Which temperature rating classification is most appropriate?
- 1110What minimum difference is required between a fixed temperature heat detector's rating and the maximum expected ambient ceiling temperature?
- 1111In which situation is a rate of rise heat detector a poor choice?
- 1114When should notification appliances be installed relative to finishes like paint?
- 1115Which mounting rule applies when a detector is installed in an air sampling or pipe network for aspirating smoke detection?
- 1116What is the maximum transport time from the most remote sampling port of an air sampling detector to the detector?
- 1117Before starting rough-in, what should the technician confirm about the building's sprinkler system for a waterflow interface?
- 1118What is the maximum height above the floor for the highest operable switch or indicator on a fire alarm control unit display, unless the AHJ approves otherwise?
- 1119What is the minimum height above the floor for the lowest switch or bottom of the text display on a fire alarm control unit?
- 1120Which device type must be installed in an elevator hoistway that has sprinklers at the top, to support elevator recall?
Maintenance
- 2001How often must the sensitivity of system smoke detectors be checked after the first check?
- 2002When must the first sensitivity check of a newly installed smoke detector be done?
- 2003Which of these methods is NOT an acceptable way to check smoke detector sensitivity?
- 2004A smoke detector's sensitivity is found outside its listed and marked range. What must be done?
- 2005How often are restorable spot heat detectors functionally tested?
- 2006What is required for nonrestorable fixed temperature spot heat detectors after 15 years in service?
- 2007How often are manual fire alarm boxes tested?
- 2008How often are notification appliances (horns, strobes, speakers) tested?
- 2009How often are sprinkler waterflow alarm devices (vane or pressure type) tested?
- 2010How often are valve supervisory (tamper) switches tested?
- 2011How often are duct smoke detectors functionally tested?
- 2012Which test is part of the duct smoke detector inspection, beyond the smoke entry test?
- 2013What is the minimum frequency for testing fire alarm control unit functions (alarm, supervisory, trouble signals) in a monitored system?
- 2014Who must perform inspection, testing, and maintenance of a fire alarm system?
- 2015Before testing begins in an occupied building, whom must the technician notify?
- 2016After testing is complete, what must the technician do with persons notified before the test?
- 2017Who is responsible for the inspection, testing, and maintenance of a fire alarm system?
- 2019Which visual inspection frequency applies to waterflow and supervisory devices under NFPA 72 (2022)?
- 2020How often should the fire alarm control unit receive a visual inspection when the system is monitored for alarm, supervisory, and trouble signals?
- 2021How often must a control unit that is NOT monitored for alarm, supervisory, and trouble signals be visually inspected?
- 2022What is the purpose of a visual inspection before a functional test of devices?
- 2023A new wall was built in an open office, splitting a room so one part has no smoke detector. Which inspection step should catch this?
- 2025What test equipment is typically used for annual functional testing of spot smoke detectors in place?
- 2026What is the correct way to functionally test a restorable heat detector?
- 2027A technician bypasses a zone for testing and forgets to restore it. What risk does this create?
- 2028The control unit shows a ground fault trouble. What is the most efficient first step to locate it?
- 2029A technician measures resistance from one conductor of a disconnected circuit to a known building ground. Which reading suggests a ground fault?
- 2030With field wiring disconnected and the far end of a Class B IDC open (EOL removed), what reading between the two conductors indicates a short?
- 2031A Class B IDC with a 4.7 kilohm EOL resistor reads infinite resistance at the panel terminals with field wiring removed. What does this indicate?
- 2032A 24 VDC NAC with a 2.2 kilohm EOL is checked with the panel in normal (supervisory) condition. Which measurement confirms the EOL is in place?
- 2033Why are notification appliances on a supervised NAC polarized (diode blocked)?
- 2034Using Ohm's law, a circuit draws 0.5 A at 24 V. What is the circuit resistance?
- 2035A 24 VDC fire alarm relay coil has a resistance of 1200 ohms. What current does it draw?
- 2036A 24 VDC panel power supply delivers 3 A to its load. How much power is that?
- 2037Two 4.7 kilohm resistors are accidentally connected in parallel at the end of an IDC. What resistance does the panel see?
- 2038A technician measures 18.2 V at the last strobe on a NAC while the panel output reads 24.0 V in alarm. What is the voltage drop on the circuit?
- 2039Strobes on the end of a NAC flash dimly and some do not flash at all during the alarm test, while the first strobes work. What is the most likely cause?
- 2040A technician finds that an addressable smoke detector reports a different device type than programmed. What type of trouble will the panel show?
- 2041Two addressable devices are set to the same address on an SLC. What is the typical result?
- 2042What does a trouble signal indicate in a fire alarm system?
- 2043Which of these conditions should produce a supervisory signal rather than a trouble signal?
- 2044A trouble signal must be annunciated within what time after the fault occurs?
- 2045When a trouble signal is silenced at the panel and the fault is not repaired, what happens?
- 2046What must the technician do when a system impairment is found during a service visit?
- 2047Which actions are part of a planned impairment procedure under NFPA 72?
- 2048After repairing a deficiency, what testing must be done?
- 2049After a change to site specific software, how many initiating devices not directly affected by the change must be tested?
- 2050A software change affects 3 devices. The system has 380 initiating devices total. How many unaffected devices must also be tested?
- 2051A site specific software change is made on a system with 1200 initiating devices. What is the maximum number of unaffected devices required to be tested?
- 2052When the control unit firmware (executive software) is changed, what must be done?
- 2053How long must records of inspection, testing, and maintenance be retained?
- 2054How long must the original acceptance test records be retained?
- 2055Where must a copy of the site specific software be kept?
- 2057How must the documentation cabinet be labeled?
- 2058What information must be recorded for each device tested in an ITM report?
- 2059Which battery marking must be on every secondary supply battery?
- 2060Under NFPA 72 (2022), what applies to rechargeable batteries used as the secondary power supply starting January 1, 2024?
- 2061Which visual condition of a sealed lead acid battery calls for immediate replacement?
- 2062What is a typical float charge voltage for a 24 V sealed lead acid battery set (two 12 V batteries)?
- 2063During an annual test, the panel is switched from primary to secondary power. What should be verified?
- 2064What is the typical end voltage used for a 24 V battery set at the end of its required standby and alarm period?
- 2065How often must the month and year marking on sealed (VRLA) batteries be checked against the manufacturer replacement date?
- 2066How is a fire alarm audible appliance's sound level checked when the ambient noise in an area has changed since acceptance?
- 2068A technician arrives for an annual test and finds a smoke detector covered with a plastic bag. What should be done?
- 2069Why should alarm verification be checked during periodic testing of smoke detector circuits?
- 2070What is the maximum alarm verification time allowed for smoke detectors under NFPA 72?
- 2071Which testing practice prevents unnecessary fire department response during an annual test?
- 2072What must be tested on the supervising station transmitter during periodic testing?
- 2073A dual path communicator loses its cellular path but keeps its IP path. What must the system do?
- 2074When replacing a failed addressable smoke detector with a new one, what must the technician verify?
- 2075Which document should be used to confirm the correct operation of each input and output during testing?
- 2076A technician finds several corroded terminals in an outdoor junction box on an IDC. Which fault is most likely to result?
- 2077An SLC with 60 addressable devices has a ground fault. The technician lifts the field wiring at device 30 and the ground fault trouble clears. Where is the fault?
- 2078A ground fault trouble appears only during heavy rain and clears in dry weather. What is the most likely cause?
- 2079A Class A IDC shows an open circuit trouble, yet every device on it still alarms when tested. Why?
- 2080A short circuit occurs on a Class A SLC that has isolator modules between groups of devices. What is the expected result?
- 2081A NAC has 12 strobes. The technician removes the EOL resistor and measures resistance across the disconnected field conductors with the meter leads in normal polarity. The reading is a few ohms. What does it indicate?
- 2082During an annual test, a horn strobe works on AC power but fails to operate after the panel transfers to batteries. Which is the most likely cause?
- 2083A technician measures 20.8 V at the last appliance in alarm with the panel on batteries. The appliances are listed for 16 V to 33 V. What is the conclusion?
- 2084A strobe NAC draws 2.4 A in alarm. The run is 250 ft one way of 12 AWG solid copper (1.93 ohms per 1000 ft). What is the voltage drop, treating the load at the end?
- 2085An owner asks to add 6 strobes drawing 0.15 A each to an existing NAC that already draws 1.7 A. The NAC is rated 2.5 A. What is the new load?
- 2086A system's measured standby current is 0.45 A and alarm current is 2.8 A. It requires 24 h standby plus 5 min alarm, with the 1.25 aging correction factor applied. What minimum battery capacity is needed?
- 2087An annual test of a 24 V sealed lead acid battery set is done. Which test shows whether the batteries can deliver their rated capacity?
- 2088How often must the battery charger of a fire alarm control unit be tested?
- 2089How are projected beam smoke detectors tested in the field?
- 2090During the annual test of an air sampling smoke detection system, what must be checked from the most remote sampling port?
- 2091How should a multicriteria detector (for example smoke plus heat) be functionally tested?
- 2092A carbon monoxide detector connected to the fire alarm system signals end of life. What must be done?
- 2093How often must door release, fan shutdown, and other emergency control functions be tested?
- 2094During an annual test, a duct smoke detector alarms but the air handler keeps running. Which item should be checked first?
- 2095An emergency voice/alarm communication system is tested. What must be verified for the speakers in each acoustically distinguishable space?
- 2096A technician is asked to replace a failed 24 V power supply board with one from a different manufacturer. What applies?
- 2097Smoke from a test aerosol triggers a detector, but the panel shows the alarm about 60 s later than expected. What feature is most likely enabled?
- 2098A remote annunciator shows a different zone description than the main panel for the same device. What should the technician do?
- 2099When should a fire alarm system service technician tag a device or system as impaired?
- 2100A smoke detector in a dusty warehouse keeps showing a maintenance alert. What is the correct response?
- 2101Ambient noise in a manufacturing room has risen to an average of 82 dBA since acceptance. The system operates in public mode. What minimum alarm level is needed now?
- 2102Two identical horns each produce 78 dBA at a test point when sounded alone. What level should be expected at that point with both sounding?
- 2103A horn measures 88 dBA at 10 ft. Assuming free field loss, what level is expected at 40 ft?
- 2104After an inspection, the service company finds deficiencies it cannot fix that day. What must the report include?
- 2105A technician measures 4.2 kilohms across a Class B IDC at the panel with field wiring disconnected. The EOL is 4.7 kilohms. What is the most likely issue?
Submittal Preparation and System Layout
- 3001Which item must be shown on fire alarm shop drawings submitted for approval?
- 3002Which document gives the reviewer the logic of what each input does to each output?
- 3003What does a riser diagram show on a fire alarm shop drawing set?
- 3004Which calculation must be included with the shop drawings for a system with secondary power from batteries?
- 3005Which sheet item helps the reviewer confirm each wall mounted strobe will cover its room?
- 3006What must record drawings show at the end of a project?
- 3007Before laying out devices in an existing building, what is the purpose of a site survey?
- 3008Which ceiling condition found during a site survey changes smoke detector spacing?
- 3009A smooth ceiling room is 60 ft by 90 ft. Detectors are laid out on a 30 ft grid. How many spot smoke detectors are needed?
- 3010A corridor is 10 ft wide. Using the 0.7S rule with S = 30 ft (every point within 21 ft of a detector), what is the maximum spacing between detectors along the centerline?
- 3011A heat detector listed for 50 ft spacing is planned for a 20 ft ceiling. The multiplier for 20 ft is 0.64. What spacing applies?
- 3012A room is 40 ft by 64 ft with a 20 ft smooth ceiling. Heat detectors are listed for 50 ft (adjusted spacing 32 ft). What is the minimum detector count on a square grid?
- 3013A projected beam detector is listed for a maximum beam length of 330 ft and a width of 60 ft. How far from the side wall may the beam be placed?
- 3014A 20 ft by 30 ft room has a 10 ft ceiling and will use one wall mounted strobe in the middle of the long wall. Which room size must be used to pick the candela?
- 3015A room is 30 ft by 30 ft with one wall mounted strobe. What minimum effective intensity applies?
- 3016A 24 V battery set must support a standby load of 0.32 A for 24 h and an alarm load of 3.6 A for 5 min. Apply the 1.25 aging correction factor of NFPA 72 (2022/2025). What capacity is required?
- 3017An emergency voice/alarm communication system has a standby load of 1.1 A and an alarm load of 6.0 A. It needs 24 h standby and 15 min of alarm, with the 1.25 aging correction factor applied. What capacity is required?
- 3018What is the required standby duration for the secondary power supply of a typical building fire alarm system before the alarm period?
- 3019A NAC uses 14 AWG stranded copper (3.14 ohms per 1000 ft). The appliances draw 1.5 A in total and the farthest one is 300 ft from the panel. What is the voltage drop, treating the load at the end?
- 3020A designer starts at 20.4 V (battery end voltage) and needs at least 16.0 V at the last appliance. The NAC draws 2.0 A and uses 12 AWG solid (1.93 ohms per 1000 ft). What is the maximum one way length, with the load at the end?
- 3021Under the IBC, when is a manual fire alarm system required in a Group A occupancy?
- 3022Under the IBC, what happens when the fire alarm activates in a Group A occupancy with an occupant load of 1,000 or more?
- 3023Under the IBC, when is a manual fire alarm system required in a Group B occupancy?
- 3024Under the IBC, a Group E occupancy needs a manual fire alarm system at what occupant load?
- 3025Under the IBC, when is a manual fire alarm system required in a Group M occupancy?
- 3026Under the IBC, which condition requires a manual fire alarm system in a Group R-2 apartment building?
- 3027Under the IBC, what fire alarm features are required in a Group R-1 hotel?
- 3028Under the IBC, when is a manual fire alarm system required in a Group F occupancy?
- 3029Under the IBC, which fire alarm requirement applies to Group I occupancies?
- 3030Under the IBC, a building is fully sprinklered and the occupant notification activates on sprinkler waterflow. What does the common exception allow for Group B or M?
- 3031Under the IBC, what is the maximum area of one fire alarm zone?
- 3032A single floor of a building covers 60,000 sq ft. What is the minimum number of IBC fire alarm zones for that floor?
- 3033A three story office building has floors of 12,000 sq ft each. How many IBC fire alarm zones are needed at minimum?
- 3034Under the IBC, what spare capacity must notification appliance circuits in employee work areas have when audible coverage is provided there?
- 3035Under the IBC, where must visible alarm notification appliances be provided?
- 3036Under the IMC, an air distribution system has a design capacity over what airflow before a smoke detector is required in the return air?
- 3037Under the IBC, a duct smoke detector connected to a building fire alarm system activates. What signal is required?
- 3038Under the IBC, how must smoke alarms in a dwelling unit with more than one alarm be connected?
- 3039Under the IBC, which feature is required in high rise buildings for occupant notification?
- 3040Which section of NFPA 101 contains the general requirements for fire detection, alarm, and communication systems?
- 3041A 500 ft long corridor has an exit at each end. Manual boxes are placed within 5 ft of each exit. How many manual boxes are needed at minimum on that floor to meet the 200 ft travel distance?
- 3042A floor has four exit stairs and the travel distance to the nearest of them is always under 150 ft. How many manual boxes are needed on that floor?
- 3043A room is 45 ft by 75 ft with a smooth 10 ft ceiling. Using 30 ft spacing for spot smoke detectors, what is the minimum count on a regular grid?
- 3044A heat detector listed for 30 ft spacing is installed on a 15 ft smooth ceiling. The multiplier for that height is 0.77. What is the adjusted spacing?
- 3045On a 12 ft ceiling, beams are 8 in. deep. How are the beams treated for spot smoke detector spacing?
- 3046Under NFPA 90A, an air handler has a supply capacity of 18,000 cfm. Where is a duct smoke detector needed on the supply side?
- 3047A design uses 18 strobes at 0.12 A and 10 horns at 0.03 A on one NAC. What is the alarm current?
- 3048Why should NAC current calculations use the appliance current at the low end of its operating voltage range?
- 3049A booster power supply is rated 8.0 A total. Its NACs serve 7.2 A of alarm load. What percentage of its capacity is used?
- 3050A small system has a standby load of 0.18 A and an alarm load of 1.9 A. It needs 24 h standby and 5 min alarm, with the 1.25 aging correction factor applied. Which standard battery size is the smallest that works?
- 3051Since the 2022 edition, what minimum correction factor must NFPA 72 battery calculations apply to the calculated amp-hour capacity to allow for battery aging?
- 3052A NAC run is 200 ft one way using 16 AWG stranded copper (4.99 ohms per 1000 ft). The alarm load is 1.0 A at the end. What is the voltage drop?
- 3053A NAC must deliver 2.5 A at 400 ft one way, and the allowed drop is 3.4 V. Which is the smallest solid copper conductor that works? (12 AWG = 1.93, 10 AWG = 1.21 ohms per 1000 ft)
- 3054Why does treating the whole NAC load as if it were at the last appliance give a conservative voltage drop result?
- 3055A 25 V speaker circuit serves 32 speakers tapped at 1 W and 8 speakers tapped at 2 W. What total power does the amplifier need to supply?
- 3056Average ambient sound in an office is 60 dBA. A horn produces 90 dBA at 10 ft. In public mode, would a person 80 ft away (free field) meet the required level?
- 3057Why should ambient sound levels be measured during the site survey of an existing building?
- 3058Corridor horns must awaken occupants in hotel rooms behind closed doors. What layout concern applies?
- 3059Which of these items is a required part of the floor plan on fire alarm shop drawings?
- 3060Why must shop drawings show ceiling heights and ceiling construction for each area?
- 3061Which documents are typically part of a fire alarm submittal package besides the drawings?
- 3062Who completes the record of completion for a new fire alarm system?
- 3063When a system is modified after acceptance, what must happen to the record documentation?
- 3064Which item on a shop drawing helps reviewers confirm the correct cable type for each area?
- 3065A design shows a notification zone layout for partial evacuation. Which information must the drawings make clear?
- 3066What is the main purpose of a fire alarm system's sequence of operation for the AHJ?
- 3067A design places a spot smoke detector 2 ft from a supply diffuser. What should the reviewer note?
- 3068A design calls for a sidewall mounted smoke detector. What placement must the drawing show?
- 3069Which standby duration does NFPA 72 require for the secondary power of an emergency voice/alarm communication system in alarm?
- 3070Which equipment locations must the shop drawings show besides initiating devices and appliances?
- 3071When should fire alarm shop drawings normally be approved by the AHJ?
- 3072A heat detector listed for 25 ft spacing is installed on an 11 ft smooth ceiling. The multiplier for that height is 0.91. What is the adjusted spacing?
- 3073A heat detector listed for 50 ft spacing is planned for a 30 ft ceiling. The multiplier is 0.34. What spacing applies?
- 3074A 20 ft wide room uses spot smoke detectors with S = 30 ft. Every point must be within 21 ft of a detector. With one row down the center, what is the maximum spacing along the row?
- 3075A speaker set on its 1 W tap produces 84 dBA at 10 ft. What level is expected at 10 ft on the 2 W tap?
- 3076An SLC is limited by the manufacturer to 40 ohms of total loop resistance. Using 18 AWG solid (7.77 ohms per 1000 ft), what is the maximum one way distance for a Class B run to the farthest device?
- 3077Within what time must the battery charger be able to recharge fully discharged secondary batteries?
- 3078Where must a smoke detector in an elevator lobby be placed in relation to the elevator doors?
- 3079A design adds new detectors to an existing panel from a different manufacturer. What must the designer confirm?
- 3080Which documents must be provided to the owner at the completion of a new system?
- 3081A system uses a digital alarm communicator transmitter (DACT). What does NFPA 72 require for its transmission means?
- 3082Under the IBC, where is a two way communication system generally required for accessible means of egress in a multistory building?
- 3083What must be stated on a shop drawing title block?
- 3084Which item should a designer include so the AHJ can see how the system responds to a waterflow signal on floor 3?
- 3085A building has a 30 ft wide by 120 ft long room with a smooth 12 ft ceiling. Spot smoke detectors use S = 30 ft. How many are needed in a single row down the center?
- 3086On a shop drawing, what does the symbol legend do?
- 3087Why must shop drawings show the location of the building's sprinkler riser and control valves?
- 3088A designer must produce battery calculations. Which current values should be used for each device?
- 3089A design places two smoke detectors 28 ft apart in a room with a smooth 10 ft ceiling. Each is 10 ft from the side walls. Does this meet the 30 ft spacing rule?
- 3090Why should notification appliance circuits be designed with some spare capacity?
Management and Supervision
- 4001When a portable ladder is used to reach an upper landing, how far must its side rails extend above the landing?
- 4002A non self supporting ladder is 16 ft long from base to support point. How far should the base be from the wall?
- 4003In construction, at what height above a lower level must workers on unprotected sides and edges have fall protection?
- 4004At what height do workers on a scaffold need fall protection under OSHA construction rules?
- 4005A technician must service a 120 V circuit feeding a fire alarm booster power supply. Under OSHA lockout/tagout rules, who may remove the lock afterward?
- 4006Which receptacles on a construction site need ground fault protection under OSHA when an assured equipment grounding program is not used?
- 4007A technician must enter a below grade vault with limited entry and possible hazardous atmosphere to reach a junction box. What applies?
- 4008Where must safety data sheets for chemicals used on a job, such as aerosol smoke or cleaning solvents, be available?
- 4009Which practice is prohibited when using a stepladder?
- 4010A technician uses a boom lift to install beam detectors. What fall protection is required?
- 4011What minimum clearance should be kept from overhead power lines of 50 kV or less when working with ladders or equipment?
- 4012A crew must work near exposed energized parts in an electrical room. Which ladder type should be used?
- 4013Under AIA A201 (2017), what does the architect's review of shop drawings check?
- 4014Under AIA A201 (2017), what must the contractor do before submitting shop drawings to the architect?
- 4015Under AIA A201 (2017), which document changes the contract sum or time and is signed by the owner, contractor, and architect?
- 4016Under AIA A201 (2017), what allows the owner to direct a change before the price is agreed?
- 4017Under AIA A201 (2017), who may order a minor change in the work that does not change the contract sum or time?
- 4018Under AIA A201 (2017), within how many days after the event must a claim normally be started?
- 4019Under AIA A201 (2017), how long is the correction period after substantial completion?
- 4020Under AIA A201 (2017), who is solely responsible for construction means, methods, techniques, sequences, and procedures?
- 4021Under AIA A201 (2017), what may the architect do with a submittal that the contract documents do not require?
- 4022A Level II technician finds a conflict between the fire alarm drawings and the ceiling plan. What is the correct way to resolve it?
- 4023Before acceptance testing of elevator recall and shunt trip, which coordination is needed?
- 4024On a new building, which trade usually installs the sprinkler waterflow and tamper switches that the fire alarm contractor then wires?
- 4025Smoke detectors are installed while drywall sanding is still going on. What should the supervisor arrange?
- 4026Under the International Fire Code, a required fire alarm system is out of service. What must happen?
- 4027On a project schedule, what is the critical path?
- 4028A wire takeoff from the drawings measures 2,400 ft of cable. The supervisor adds 10 percent for waste and routing. How much cable should be ordered?
- 4029A project has 120 devices. Each takes about 0.75 labor hours to install and terminate. With a crew of two technicians, how many working hours will it take?
- 4030Why should fire alarm devices and equipment be ordered only after the submittals are approved?
- 4031Which qualification does NFPA 72 accept for personnel who perform inspection, testing, and maintenance?
- 4032At the start of each work day on a fire alarm job, which supervisor action best supports safe and efficient work?
- 4033A customer asks the technician to disable a nuisance detector permanently. What should the supervisor do?
- 4034Which record helps a supervisor prove what work was done on a given day on site?
- 4035A crew must braze a pipe support near an area with active smoke detectors. Which step should the supervisor arrange first?
All questions individually: NICET Fire Alarm Systems Level III
Installation
- 1001A Level II technician proposes feeding a new fire alarm control unit from a GFCI protected receptacle circuit in the electrical room. What should the Level III project lead require instead?
- 1002During a site walk you find the breaker that serves the fire alarm control unit. Which condition must you verify for that circuit disconnecting means?
- 1003On a tenant improvement project the crew finds old fire alarm cable above an accessible ceiling that is no longer terminated at either end and is not tagged for future use. What does the NEC require?
- 1004While inspecting rough-in, you see fire alarm cable laid directly on the lay-in ceiling tiles and tied to the ceiling grid wires. What is the correct direction to the installer?
- 1005Power-limited fire alarm cable must be run without raceway through a ceiling cavity that is used as a return air plenum. Which cable type is required?
- 1006An electrician wants to pull power-limited fire alarm conductors into the same conduit as 120 V lighting branch circuit conductors to save time. What is the correct ruling?
- 1007Your crew has run fire alarm cable through a 2-hour rated corridor wall. What must you confirm before the wall is closed up?
- 1008Which description matches pathway survivability Level 3 in NFPA 72?
- 1009On a Class A initiating device circuit, the specifications require the outgoing and return conductors to follow separate routes. Where does NFPA 72 permit them to run together in the same cable or raceway?
- 1010Which performance does a Class X pathway add compared with a Class A pathway?
- 1011What type of pathway is a Class N pathway?
- 1012The general contractor asks for smoke detectors to be installed now, while drywall sanding is still under way, so the area can be protected. What is the proper approach?
- 1013An addressable relay module will drop out the hold-open power for a smoke damper actuator. Where must the module be located relative to the controlled component?
- 1014During commissioning, the elevator lobby smoke detector on the designated recall level is activated. Where should the elevators go?
- 1015Which detector activations must cause the visual fire warning symbol in the elevator car to flash?
- 1016Heat detectors are being installed to shunt trip the elevator power in a sprinklered machine room. Which installation meets NFPA 72?
- 1017The sprinkler contractor proposes using the hoistway waterflow switch to initiate elevator shunt trip. The switch has a 60 second retard. What is the correct ruling?
- 1018A duct smoke detector is connected to the building fire alarm system to shut down an air handler. When it activates, what signal does NFPA 72 normally require it to initiate at the control unit?
- 1019What happens to doors held open by fire alarm controlled magnetic door holders when building power fails?
- 1020An access-controlled egress door is electrically locked. What must happen to it when the building fire alarm system activates?
- 1021The fire alarm control unit will be in a storage room that is not continuously occupied. What detection does NFPA 72 require at the control unit location?
- 1023What mounting height does NFPA 72 require for the operable part of a manual fire alarm box?
- 1024Where must manual fire alarm boxes be placed in relation to exits, when they are required?
- 1025A lobby has a group of entrance doors whose total width exceeds 40 ft. How should manual fire alarm boxes be located?
- 1026During acceptance testing of a valve supervisory switch on an OS&Y valve, when must the off-normal supervisory signal appear?
- 1027A waterflow switch is tested by flowing water through the inspector's test connection. What performance does NFPA 72 require?
- 1028A technician reports that a vane-type waterflow switch with its retard set at maximum produced an alarm 120 seconds after the test valve was opened. What is the correct supervisory decision?
- 1029Where must wall-mounted visible notification appliances be installed?
- 1030Where wall-mounted audible-only appliances are installed, what height does NFPA 72 require?
- 1031Three strobes are visible from one location in an open office. What must be confirmed during commissioning?
- 1032A strobe in a hotel guest room for a guest with hearing loss is mounted 30 in below the ceiling. What minimum intensity is required?
- 1033What signal characteristic must audible appliances in sleeping areas of a new hotel produce to wake occupants?
- 1034What portion of a new fire alarm system must be tested during initial acceptance testing?
- 1035After a change to site-specific software that is not supposed to affect most of the system, which reacceptance testing is required?
- 1037How must the cabinet that holds the fire alarm record documents be identified?
- 1038How must a copy of the site-specific software be kept for a new system?
- 1039What is the typical format NFPA 72 suggests for presenting the sequence of operations in shop drawings and record documents?
- 1040When is the record of completion for a new fire alarm system prepared and provided?
- 1041During a site visit you discover an electrician has relocated six smoke detectors to avoid new ductwork, and the approved shop drawings no longer match. What is the correct Level III response?
- 1042What does the term as-built drawings, or record drawings, mean in the closeout package?
- 1043Before field devices are connected, your crew plans to test new cable runs with an insulation resistance tester. What is the main precaution?
- 1044Which of the following must be confirmed for two-wire smoke detectors connected to a conventional initiating device circuit?
- 1045Lead-acid batteries for the fire alarm system are delivered to the site. Which marking must the batteries carry?
- 1046A ceiling smoke detector on the drawings lands 2 ft from a supply air diffuser. What is the minimum distance you should direct the installer to maintain?
- 1047A spot smoke detector must be mounted on a sidewall because the ceiling is inaccessible. Where must it be placed?
- 1048An installer mounts a spot heat detector on a wall. Which location complies with NFPA 72?
- 1049In a room with a peaked ceiling, where should the first row of spot smoke detectors be placed?
- 1050During pretest, a technician activates a detector in Room 214 and the annunciator shows Room 241. What is the correct fix before acceptance?
- 1051Before starting a test on an existing monitored system, who must the Level III make sure is notified?
- 1052What must be done when testing of a monitored system is finished for the day?
- 1053You will witness acceptance testing of the elevator recall functions in a new building. Who should you schedule to be on site?
- 1054During acceptance testing, how do you verify ground fault monitoring on each circuit?
- 1055During acceptance testing, primary power to the control unit is disconnected. What result shows correct operation?
- 1056What secondary power duration does NFPA 72 require for a typical protected premises fire alarm system without voice evacuation?
- 1057For an in-building emergency voice/alarm communications system, how long must the secondary supply operate in alarm after 24 hours of standby?
- 1058Your project specifies a listed standby generator as part of the secondary supply. Under NFPA 72, what minimum battery capacity is still needed?
- 1059Which items does NFPA 72 list as part of the record documentation turned over to the owner at completion?
- 1060How long must the fire alarm record documentation (record drawings, record of completion, sequence of operation) be kept?
- 1061What qualification does NFPA 72 list as acceptable for persons who prepare fire alarm system plans and specifications?
- 1062Who must be able to show evidence of their qualifications to the AHJ on a fire alarm project?
- 1063Under the IBC, what is the maximum floor area of a single fire alarm zone in a building that requires zoning?
- 1064How does NFPA 70 require fire alarm circuits to be identified in the field?
- 1065A technician has looped an unbroken conductor under the terminal screw of each detector base on a Class B initiating circuit. Why is this a problem?
- 1066A technician suggests adding a T-tap from the middle of a conventional notification appliance circuit that ends in an end-of-line resistor. Why should you reject this?
- 1067To which UL standard must a fire alarm control unit be listed?
- 1068A submittal for duct smoke detectors lists only a UL 268 listing. Which listing should you ask for instead?
- 1069Where are the installation requirements for carbon monoxide detection in a commercial building located for current NFPA 72 projects?
- 1070Which NFPA standard covers integrated testing of fire protection and life safety systems that interact with each other?
- 1071Your crew must connect new devices to an existing system in an occupied hospital, which will take the system out of service for part of a shift. What should happen first?
- 1072Under NFPA 101, what must happen when a required fire alarm system is out of service for more than 4 hours in a 24-hour period?
- 1074A remote booster power supply is added to drive strobes on the third floor. What must the Level III make sure is documented and done?
- 1075A building has a central station monitoring contract. What must be posted at the protected premises to show compliance?
- 1076On an addressable system, why does the Level III insist that the remote annunciator be located where the AHJ approves, usually at the fire department entrance?
- 1077The HVAC contractor has not yet started the air handlers when the fire alarm acceptance test is scheduled. What should the Level III project lead do?
- 1078Before final inspection, the sprinkler contractor asks to monitor the fire pump. Which conditions are typically supervised at the fire alarm system for an electric fire pump?
- 1079Which of the following is the best way to deal with a scope gap discovered mid-project, where the contract drawings show no detection in a new IT room that the code requires?
- 1080Why should a Level III verify the listing of every substituted device before it is installed?
- 1081During rough-in inspection on a new office building, you find several fire alarm junction boxes above a hard lid ceiling with no access panel. What is the main concern?
- 1082A fire alarm interface relay will release the hold-open power for corridor smoke doors. How should the release be wired so it is fail-safe?
- 1083On a project where the AHJ requires a fire watch during the cutover from the old system to the new one, who is normally responsible for providing it?
- 1084A technician sets the panel to bypass the entire third floor while the ceiling contractor works there. Which control does the Level III need to ensure?
- 1085Which situation requires the installing contractor to perform reacceptance testing?
- 1086What is the purpose of the commissioning or acceptance test report signed at the end of the project?
- 1087A field change adds a new corridor with no manual boxes or notification on the approved plans. Which document change must the Level III make sure is completed?
- 1088Which statement correctly describes the AHJ's role during the acceptance test?
- 1089Before the final acceptance test, who should receive training on operating the fire alarm system?
- 1090At the pre-acceptance inspection you find spot smoke detectors installed in the pockets between deep beams rather than on the bottom of the beams as shown on the approved drawings. What is the correct response?
Maintenance
- 2001A new system with 400 spot smoke detectors was accepted last month. When must the first sensitivity test of those detectors be performed?
- 2002Your service team has completed the first two required sensitivity tests on a building's smoke detectors and every detector was within its listed range both times. What may the ITM manager do?
- 2003Which method does NOT measure smoke detector sensitivity and therefore cannot be used to satisfy the sensitivity test requirement?
- 2004A sensitivity report shows 12 detectors outside their listed sensitivity range. What does NFPA 72 require for those detectors?
- 2005How often must the functional test of system smoke detectors be performed?
- 2006During annual testing, how should a restorable spot-type heat detector be tested?
- 2007A building has fixed-temperature, nonrestorable spot heat detectors that were installed 15 years ago. What does NFPA 72 require at this point?
- 2008How is a nonrestorable line-type heat detector checked during periodic testing?
- 2009How often must manual fire alarm boxes be functionally tested?
- 2010Which test frequency does NFPA 72 assign to mechanical (vane) and pressure-type waterflow alarm devices?
- 2011Under NFPA 25, how often must sprinkler control valve supervisory switches be tested?
- 2012How often must audible and visible notification appliances be functionally tested?
- 2013During routine annual testing of an unchanged building, must a technician take sound pressure level readings at every audible appliance?
- 2014A load voltage test shows the fire alarm battery voltage under load falls below the battery manufacturer's minimum. What is the correct action?
- 2015How often must the emergency control functions of a fire alarm system, such as elevator recall and fan shutdown, be tested?
- 2016Which party is responsible for the inspection, testing, and maintenance of a building fire alarm system?
- 2017A property manager wants to hand over ITM responsibility to your company. What does NFPA 72 require for that delegation?
- 2018Which description best defines an emergency impairment?
- 2019A water leak damages a notification appliance circuit at 2 a.m. and the night guard calls your service line. What is the correct order of priorities?
- 2020What must happen before an impaired system is returned to service?
- 2021A student pulls a manual fire alarm box as a prank. How does NFPA 72 classify this alarm?
- 2022A dirty smoke detector that has not been cleaned in years goes into alarm with no fire. How does NFPA 72 classify this?
- 2023A maintenance worker sets off a detector with welding smoke while working without a hot work permit. How is this unwanted alarm classified?
- 2024Under NFPA 72, what does a semiannual test frequency mean in terms of allowed scheduling window?
- 2025A technician performed the previous annual test in March. Using the NFPA 72 definition of annual, which next test date still complies?
- 2026How long must inspection, testing, and maintenance records be retained under NFPA 72?
- 2027Which information must an inspection and testing report contain to be useful under NFPA 72?
- 2028Before the annual test of a building, you are asked to write a test plan. What is its main purpose under NFPA 72?
- 2029The building has a clean agent suppression system released by the fire alarm system. What must be done before testing detectors in the protected room?
- 2030Where testing personnel leave a system with an uncorrected deficiency at the end of a visit, what should the Level III service manager require?
- 2031During the annual inspection you notice that a large open office has been divided into small offices with full-height walls since the last test. What should you do?
- 2032How must single- and multiple-station smoke alarms in dwelling units be handled with respect to age?
- 2033A carbon monoxide detector connected to the fire alarm system indicates an end-of-life signal. What is the correct response?
- 2034An engine-driven generator serves as part of the fire alarm system's secondary power. Which standard governs its testing?
- 2035An intermittent ground fault trouble comes and goes on a system with eight circuits. What is an efficient troubleshooting strategy?
- 2036A notification appliance circuit is in trouble. With the field wiring disconnected from the panel, you measure the resistance across the two field conductors and read an open circuit instead of the end-of-line resistor value. What does this indicate?
- 2037A short on a signaling line circuit drops out 120 devices on a large floor. Which design feature limits how many devices are lost to one short?
- 2038During the annual inspection of a 24 VDC system, you measure 27.3 V across the battery terminals with the charger connected. What does this reading usually indicate?
- 2039During the annual test of a duct smoke detector, which check is needed besides the functional alarm test?
- 2040During annual testing of an air-sampling smoke detection system, what transport time requirement applies to the farthest sampling port?
- 2041An addressable smoke detector reports a maintenance alert because its drift compensation has reached its limit. What is the correct response?
- 2042Which personnel does NFPA 72 recognize as qualified to perform inspection, testing, and maintenance of fire alarm systems?
- 2043Before the annual visit at a central station monitored building, what should the technician confirm with the central station operator?
- 2044Annual testing reveals that a beam smoke detector alarms at the correct attenuation filter, but its alignment is off and it reports trouble every few days. What is the right action?
- 2045Which description fits a central station service under NFPA 72?
- 2046A university monitors all of its buildings from a supervising station that it owns and staffs itself. What type of supervising station is this?
- 2047Under what circumstance is a remote supervising station system used?
- 2048Which of the following is one of the service elements a central station must provide?
- 2049To which UL standard is a central station listed?
- 2050After receiving a fire alarm signal, how quickly must a central station retransmit it to the public fire service communications center?
- 2051A central station receives a supervisory signal for a closed sprinkler valve. What action does NFPA 72 require?
- 2052A new account uses a digital alarm communicator transmitter. Which arrangement meets NFPA 72?
- 2053A building's fire alarm communicator was converted to an IP path with cellular backup. What must be verified during the annual test?
- 2054A site has 300 fixed-temperature nonrestorable spot heat detectors that reached 15 years of service. If the owner chooses sampling rather than replacement, how many must be sent for laboratory testing?
- 2055A site-specific software change affects only the elevator recall programming. The system has 620 initiating devices not affected by the change. How many of them must be tested during reacceptance?
- 2056A software change affects one floor of a system with 300 initiating devices not affected by the change. How many unaffected initiating devices must be tested?
- 2057Smoke detectors in a building were installed in January 2024. Following the standard sequence, by when must the second sensitivity test be done?
- 2058A technician leaves the panel in walk test mode at the end of the day. Why is this a serious problem?
- 2059During the annual inspection you find that a painter has painted several smoke detectors along with the ceiling. What should you do?
- 2060Months after a renovation, your technician finds plastic dust covers still on several smoke detectors. How should this be handled?
- 2061A tenant has placed a large storage cabinet in front of a manual fire alarm box. What is the proper handling?
- 2062A new tenant hung a large banner that blocks the view of a strobe in an open area. What should the inspection report say?
- 2063May inspection and testing records be kept in electronic form?
- 2064Who should receive a copy of the completed annual inspection and testing report?
- 2065An ITM manager reviews unwanted alarm logs and sees repeated activations from one smoke detector next to a break room toaster. What is the best long-term response?
- 2066A building uses positive alarm sequence. After an automatic detector alarms, how long does staff have to acknowledge the signal before general alarm?
- 2067Under positive alarm sequence, after acknowledgment, how much investigation time is allowed before the general alarm must sound?
- 2068To which type of initiating device may the alarm verification feature be applied?
- 2069The panel shows a trouble signal that the building engineer silenced yesterday. The fault has not been repaired. What should the control unit do?
- 2070Notification appliances have been silenced after an alarm on the first floor. A detector on the fourth floor then goes into alarm. What must happen?
- 2071Which signal type indicates an off-normal condition of a fire suppression system, such as a closed control valve or low air pressure?
- 2072A sprinkler contractor will close a control valve to repair a branch line. From the fire alarm perspective, how should this be managed?
- 2073What are the duties of a person assigned to a fire watch during a fire alarm impairment?
- 2074A 1990s control unit has no replacement parts available and the manufacturer no longer supports it. What is the best ITM manager recommendation to the owner?
- 2075Your company services 60 buildings. Which practice best supports a compliant ITM program?
- 2076After a building was struck by lightning, the panel shows trouble on several circuits and the communicator. What should the service response include?
- 2077The owner asks whether a smoke detector that tested within its listed range can be left in service despite being 14 years old. What does NFPA 72 base the decision on?
- 2078Which test result best indicates a failing secondary power supply that needs immediate action?
- 2079A remote annunciator is dark during the annual inspection, but the main panel works normally. Which is the most likely category of problem to check first?
- 2080A system has repeated nuisance alarms from duct detectors when air handlers start. What is the most likely cause to investigate?
- 2081During the annual test, door holders on a corridor release correctly when the fire alarm activates, but one door does not fully close. Whose deficiency is it and what do you do?
- 2082Which statement about the presignal feature is correct?
- 2083The owner wants to stop the annual test of the elevator recall because it disrupts tenants. What should you advise?
- 2084During the annual inspection the record documentation cabinet is empty and the owner cannot find the drawings. What should the Level III recommend?
- 2085An existing system tests correctly, but you notice the building's occupancy changed from offices to a daycare. What should your report recommend?
- 2086Which action best prevents unintentional alarm transmission when a technician must replace a detector on a monitored system?
- 2087Which of these is the correct sequence when a deficiency found during inspection cannot be fixed on the spot?
- 2088Which measurement is typically used when sound pressure levels are verified after a renovation?
- 2089An ITM contract requires a quarterly visual inspection of a central station signaling path that the code requires only annually. Which frequency applies to the service company?
- 2090A client asks why a semiannual waterflow test produced a signal at the central station 75 seconds after the inspector's test valve was opened. Does this meet the requirement?
Submittal Preparation and System Layout
- 3001A panel draws 0.45 A in standby and 2.10 A in alarm. The system needs 24 hours of standby followed by 5 minutes of alarm, and you apply the 1.25 aging correction factor of NFPA 72 (2022/2025). What is the minimum battery capacity?
- 3002A system draws 0.30 A in standby and 1.80 A in alarm. With 24 hours standby, 5 minutes alarm, and no margin, what is the required battery capacity?
- 3003An in-building emergency voice/alarm communications system draws 0.80 A standby and 6.0 A in alarm. What alarm duration must the battery calculation use after the 24-hour standby?
- 3004In a battery calculation, which current values should be used for each device?
- 3005A 24 VDC notification circuit has 10 strobes drawing a total of 1.5 A. The farthest strobe is 300 ft from the panel on 14 AWG solid wire with 3.07 ohms per 1,000 ft. What is the approximate voltage drop at the end?
- 3006A strobe circuit is designed to start at a worst-case panel source voltage of 20.4 V. The strobes are listed for 16 to 33 V. What is the maximum allowable voltage drop on the circuit?
- 3007A 12 AWG stranded circuit has a resistance of 1.98 ohms per 1,000 ft. The load is 2.0 A at the end of a 250 ft run. What is the voltage drop?
- 3008A NAC calculation shows a 5.2 V drop, but only 3.5 V is allowed. Which change will reduce the drop the most?
- 3009What is the listed spacing of spot-type heat detectors in a room with a smooth ceiling 9 ft high, if the detector is listed for 50 ft?
- 3010A heat detector listed for 50 ft spacing is installed on a smooth ceiling 15 ft high. The ceiling height multiplier for over 14 up to 16 ft is 0.77. What is the adjusted spacing?
- 3011A heat detector listed for 30 ft spacing is installed on a smooth ceiling 21 ft high. The multiplier for over 20 up to 22 ft is 0.58. What is the adjusted spacing?
- 3012Under the 0.7 rule, how far may a spot-type detector with a nominal 30 ft spacing be from any point on the ceiling?
- 3013On a smooth ceiling, spot smoke detectors at a 30 ft spacing are installed. What is the maximum distance from a detector to a side wall?
- 3014A room is 60 ft by 90 ft with a smooth flat ceiling. Using spot smoke detectors at a 30 ft square spacing, how many detectors are needed?
- 3015A smooth ceiling has solid joists 10 in deep spaced 3 ft on center. How does this affect spot heat detector spacing?
- 3016A ceiling has beams 12 in deep spaced 6 ft on center. How is spot heat detector spacing adjusted?
- 3017A warehouse ceiling has beams 24 in deep and 10 ft on center. How should heat detection be laid out?
- 3018A sloped ceiling rises 2 ft over a horizontal run of 10 ft. Is it a sloping ceiling under NFPA 72 detector placement rules?
- 3019For a peaked ceiling, where must the first row of spot detectors be located?
- 3020When laying out detectors on a sloped ceiling, which dimension is used for spacing beyond the first row?
- 3021Per NFPA 72 Table 18.5.5.4.1(a), which effective intensity is required for a single wall-mounted strobe in a 30 ft by 30 ft room?
- 3022A conference room is 38 ft by 40 ft. Using one wall-mounted strobe per the room spacing table, which minimum rating would you pick?
- 3023In a corridor 10 ft wide and 180 ft long, how must visible appliances be spaced?
- 3024The average ambient sound level in a factory is 85 dBA. What is the minimum average alarm level required for public mode audible signaling?
- 3025A private mode alarm is designed for a control room with 60 dBA average ambient. What minimum level is required?
- 3026What audible level is required at the pillow in sleeping areas, at a minimum?
- 3027What is the maximum sound pressure level allowed for audible notification appliances?
- 3028In a voice evacuation system, which metric is commonly used to verify that messages are intelligible?
- 3029A large atrium with hard surfaces will have speakers. What design approach best supports intelligibility?
- 3030Which item must shop drawings include under NFPA 72?
- 3031Which document describes what each initiating device causes the system to do, such as recall elevators or release doors?
- 3032What does a riser diagram show on fire alarm shop drawings?
- 3033A plan reviewer rejects your shop drawings because product data sheets are missing for several devices. Why does this matter?
- 3034Under the IBC, a manual fire alarm system is required in a Group B occupancy when which condition is met?
- 3035Under the IBC, when is a manual fire alarm system required in a Group E occupancy?
- 3036Under the IBC, a manual fire alarm system is required in a Group A occupancy when which threshold is met?
- 3037Under the IBC, a Group A occupancy with 1,000 or more occupants requires which type of notification?
- 3038Under the IBC, which condition triggers a fire alarm system in a Group R-2 apartment building?
- 3039Under the IBC, when does a Group M occupancy require a manual fire alarm system?
- 3040Under the IBC, when is a manual fire alarm system required in a Group F occupancy?
- 3041Under NFPA 101, when is a fire alarm system required in a new business occupancy?
- 3042Under the IBC and IMC, smoke detectors in return air ducts of an HVAC unit are generally required above which airflow?
- 3043A plans reviewer asks for proof that two-wire smoke detectors will work with your selected control unit. What should you submit?
- 3044A speaker circuit has 22 speakers tapped at 1 W and 8 speakers tapped at 2 W. The design rule leaves 20 percent spare amplifier capacity. What minimum amplifier rating is needed?
- 3045A 24 V power supply has a 6 A output. Strobes on four circuits draw 1.4 A, 1.6 A, 1.2 A, and 1.5 A in alarm. Is the supply adequate?
- 3046Why must strobe current values be taken at the lowest operating voltage when sizing circuits?
- 3047Where more than two visible appliances are in the field of view, what must the design provide?
- 3048A strobe is mounted on the ceiling of a 30 ft by 30 ft room with a 10 ft ceiling. Which table should be used to select its rating?
- 3049In sleeping rooms, what is the minimum visible appliance rating when the appliance is more than 24 in below the ceiling?
- 3050What is the maximum distance allowed between the pillow and the visible appliance in a sleeping room?
- 3051Which document must the designer prepare before a mass notification system is designed?
- 3052A shop drawing shows the pathway class for each circuit. Why is this information important for review?
- 3053A designer must document where pathway survivability Level 2 or 3 is required. Which system type most often triggers this?
- 3054Which item is required in the documentation for a system using a performance-based detection design?
- 3055What is the main purpose of the record drawings (as-built drawings) for a fire alarm system?
- 3056An engineer of record returns your shop drawings marked 'Revise and Resubmit'. What should you do?
- 3057During review, you find that the architect's reflected ceiling plan has changed, moving lights to where you placed smoke detectors. What should the Level III do?
- 3058A large open office has ceiling-mounted supply diffusers. How far must spot smoke detectors be from them?
- 3059Which ceiling height condition generally points toward projected beam or air sampling detection rather than spot smoke detectors?
- 3060What does stratification mean for smoke detector design?
- 3061A projected beam smoke detector is being laid out. Which source governs the beam spacing and the distance to the ceiling?
- 3062Which information must the designer show for an air sampling smoke detection system?
- 3063Smoke detectors are used to release doors held open in a smoke barrier. Where are they typically located?
- 3064When a building has a smoke control system, what must fire alarm documents coordinate with?
- 3065Where must the location of the elevator recall initiating devices be shown?
- 3066Which document should a designer reference to find the elevator recall requirements on the elevator side?
- 3067A sprinklered Group B building has 600 occupants. Under the IBC, which feature can allow omitting most manual fire alarm boxes?
- 3068In a fully sprinklered building where most manual boxes were omitted under the IBC exception, how many manual boxes are still required?
- 3069Under the IBC, which occupancy group requires an automatic smoke detection system in corridors in most cases, such as nursing homes?
- 3070Under the IBC, which occupancy requires smoke alarms in sleeping units, even where a fire alarm system is installed?
- 3071In a high-rise building, which notification system does the IBC require?
- 3072Under NFPA 101, which occupancy generally requires a fire alarm system for any new building regardless of size?
- 3073A plan reviewer notes that the building's code is NFPA 101 and the IBC, and the two disagree on a threshold. How should the designer proceed?
- 3074Why should the design documents state the adopted code editions?
- 3075A plan review comment asks you to show the location of the fire alarm control unit and annunciator. What usually governs where they go?
Management and Supervision
- 4001Under OSHA construction rules, at what height must workers on a walking-working surface with an unprotected edge generally be protected from falls?
- 4002A technician uses a portable extension ladder to reach a roof edge. How far must the side rails extend above the upper landing?
- 4003A non-self-supporting ladder is 20 ft long to the support point. About how far from the wall should its base be?
- 4004Your crew must work on a 120 V circuit that feeds the fire alarm control unit. What does OSHA require before work begins on it?
- 4005On a construction site, what does OSHA require for 120 V, 15 and 20 A temporary receptacles used by your crew?
- 4006A technician works from the platform of a boom-supported aerial lift. What fall protection is required?
- 4007Your crew drills many holes in concrete for device mounting. Which OSHA standard addresses the dust hazard?
- 4008How long must an employer keep OSHA 300 logs of work injuries and illnesses?
- 4009A worker is killed on a jobsite. Within how many hours must the employer report it to OSHA?
- 4010A worker suffers an amputation of a fingertip on site. Within how many hours must the employer report it to OSHA?
- 4011OSHA uses the term competent person. What is it?
- 4012Under OSHA rules, how must safety training be provided to workers?
- 4013A foreman notices a technician using a ladder with a cracked rail. What is the supervisor's duty?
- 4014A technician must enter a tank room that is a permit-required confined space. What should the supervisor do?
- 4015Under the NICET Code of Ethics, what should a certified technician do if asked to sign off on a test that was not performed?
- 4016Under the NICET Code of Ethics, what may a certified technician do regarding work outside their certified area?
- 4017Under the NICET Code of Ethics, what should a technician do when they learn that an installation endangers public safety and the employer refuses to correct it?
- 4018How should a NICET certified technician use their certification in advertising?
- 4019Under AIA A201, who is solely responsible for construction means, methods, techniques, sequences, and procedures?
- 4020Under AIA A201, are shop drawings part of the Contract Documents?
- 4021Under AIA A201, what must the Contractor do before sending shop drawings to the Architect?
- 4022Under AIA A201, what is a Change Order?
- 4023Under AIA A201, what is a Construction Change Directive?
- 4024Under AIA A201, the Architect orders a minor change in the work that does not affect cost or time. What is this called?
- 4025Under AIA A201, how long after Substantial Completion must the Contractor generally correct work found not to conform?
- 4026Under AIA A201, how soon must a Claim be made after the claimant first recognizes the condition giving rise to it?
- 4027Under AIA A201, what should the Contractor do on discovering an error between the drawings and specifications?
- 4028Under AIA A201, what does Substantial Completion mean?
- 4029A fire alarm subcontractor's crew will be late because a ceiling is not closed in. What is the best project management response?
- 4030A project manager prepares a bid for a fire alarm installation. Which item is most essential to include from the specification?
- 4031Which estimate component covers costs like insurance, office rent, and accounting that are not tied to a single job?
- 4032On a construction contract, what is retainage?
- 4033What does a payment bond protect?
- 4034What does a performance bond guarantee?
- 4035A Level III supervises a Level I technician installing devices. Which supervision practice best ensures quality?
- 4036A technician repeatedly fails to follow lockout procedures. What should the supervisor do?
- 4037Which document should be created at the end of each workday on a large fire alarm project?
- 4038A schedule shows fire alarm acceptance testing three days before the certificate of occupancy date. What is the main risk?
- 4039Which approach helps a project manager control material costs on a fire alarm job?
- 4040A manufacturer releases a firmware update for the control unit after installation. How should the project manager handle it?
- 4041A worker is exposed to noise of 95 dBA during testing of horns. What should the supervisor ensure?
- 4042A project has 4,800 labor hours estimated for installation. After 60 percent of the work is complete, 3,300 hours have been used. If the trend continues, about how many total hours will the job take?
- 4043A fire alarm job has a contract value of $240,000. Direct costs are $180,000 and allocated overhead is $36,000. What is the net profit as a percentage of the contract value?
- 4044The owner's representative asks your technician on site to add four strobes in a new room. What should the Level III project manager require before the work proceeds?
- 4045A subcontract requires the fire alarm contractor to carry insurance naming the general contractor as additional insured. What should the project manager provide before starting work?
All questions individually: NICET Fire Alarm Systems Level IV
Installation, Planning and Maintenance Management
- 1001A hospital addition ties a new fire alarm network node into the existing campus system, smoke control, elevator recall and door release. Which document governs the testing that proves these interconnected systems work together as intended?
- 1002On a commissioning project, which document is written by the design team to explain how the owner's project requirements will be met, including code basis, assumptions and system descriptions?
- 1003Under the commissioning process described in NFPA 3, who normally develops the owner's project requirements (OPR)?
- 1004Six addressable smoke detectors are added to an existing loop, and the program is edited to map them to an existing elevator recall output. What reacceptance testing is required?
- 1005After a change to site-specific software, NFPA 72 requires testing of all functions known to be affected by the change. What additional sample of initiating devices not directly affected must also be tested?
- 1006Under NFPA 72, who is responsible for the inspection, testing and maintenance of a fire alarm system and its interconnected emergency control functions?
- 1007You are setting up an ITM program for a 40 story office tower. How often must sensitivity of the spot-type smoke detectors be checked after the first year test, assuming each result stays within the listed range?
- 1008In the ITM schedule you are building, how often must waterflow alarm devices and valve supervisory switches be functionally tested?
- 1009A facility has nonrestorable fixed temperature spot heat detectors installed 15 years ago. What does NFPA 72 require for these detectors?
- 1010Before starting the annual test of a monitored system in a hotel, which step does NFPA 72 require regarding signal recipients?
- 1011A data center fire alarm system interfaces with a preaction releasing panel, HVAC shutdown and door unlocking. What must be in place before the periodic test begins?
- 1012Under the International Fire Code, a required fire alarm system is out of service. What must happen?
- 1014A fire alarm contractor agrees to install a high-rise voice system for a fixed total price regardless of the actual cost. Which contract type is this, and who carries the risk of cost overruns?
- 1015An owner wants to pay the contractor's actual costs plus a fee, but with a ceiling the price cannot exceed. Which contract arrangement fits?
- 1016A campus retrofit is priced at a fixed amount per installed device because the final device count is not known at bid time. Which contract type is this?
- 1017The general contractor withholds 10 percent of each progress payment from the fire alarm subcontractor until the project is accepted. What is this withheld money called?
- 1018A contract states that the contractor will owe the owner 1,500 dollars for each calendar day the fire alarm acceptance test is late. What is this provision called?
- 1019Which bond protects the owner if the fire alarm contractor fails to complete the work according to the contract?
- 1020A supplier of fire alarm devices has not been paid by the electrical contractor. Which bond on a public project protects that supplier?
- 1021In a critical path schedule for a high-rise fire alarm installation, what characterizes the critical path?
- 1022An activity in your project schedule has an early start of day 12 and a late start of day 19. How much total float does it have?
- 1023Your estimated direct cost for a voice evacuation retrofit is 84,000 dollars. Company policy requires a 30 percent gross margin on the selling price. What selling price meets that policy?
- 1024A sales estimator applies a 25 percent markup to a job cost of 60,000 dollars. What gross margin results on the selling price?
- 1025A takeoff shows 480 addressable devices, each estimated at 0.75 labor hours including wiring terminations. With a crew of 3 technicians working 8 hour days, about how many working days will device installation take?
- 1026Last year your fire alarm company had 450,000 dollars of indirect overhead and 1,800,000 dollars of direct labor cost. If overhead is applied as a percentage of direct labor, what rate should the estimators use?
- 1027A service department has annual fixed costs of 360,000 dollars and earns a contribution margin of 40 percent on each dollar of revenue. What annual revenue is needed to break even?
- 1028Your service department must perform 1,600 annual inspections averaging 6 labor hours each. Each technician delivers about 1,400 billable hours per year. How many technicians are needed for this inspection workload alone?
- 1029On a percentage of completion job, you have billed 60 percent of the contract value while costs incurred represent 48 percent of the estimated total cost. How is the job reported on the work in progress schedule?
- 1030The owner asks your field crew to add 14 speakers in a new conference wing that is not in the contract scope. What should the project manager do before the crew starts the extra work?
- 1031A supplier who furnished control units for a private office building has not been paid. Which legal remedy lets the supplier place a claim against the improved property itself?
- 1032Which type of insurance covers medical costs and lost wages for a fire alarm technician who is injured falling from a ladder on the job?
- 1033A design department manager reviews staffing. Which credential does NFPA 72 list as one way for a fire alarm system designer to show qualification?
- 1034At the end of a new building project, which item is required at the completion of a new fire alarm installation in addition to record drawings and site-specific software?
- 1035When should spot-type smoke detectors normally be installed in a building under construction?
- 1036A building owner asks whether an existing fire alarm system must be upgraded to the newly adopted NFPA 72 edition. Absent other requirements, what is the general rule?
- 1037A service sales manager is preparing an RFP response for the annual testing of a 300 building portfolio. Which item should drive the labor estimate most directly?
- 1038Your company is replacing an obsolete control unit but keeping the existing conventional 2-wire smoke detectors. What must be confirmed before the new unit is ordered?
- 1039When a fire alarm contractor's project manager plans a large project, why is a schedule of values submitted early in the job?
- 1040A project manager is told a key activity on the critical path will finish 5 days late. Which response directly protects the project completion date?
- 1041Which closeout item gives the owner the narrative description of the system, operator instructions and the procedures for routine maintenance and testing?
- 1042A construction manager asks when the fire alarm contractor's warranty period normally starts. What is the most common contract answer?
- 1043At the acceptance test for a new voice evacuation system, the contractor should already have completed which step?
- 1044A cost report shows a job is 50 percent complete, with 62,000 dollars spent against a 110,000 dollar total cost budget. What is the projected cost at completion if the overrun rate continues?
- 1045Which business record should a fire alarm department manager review to compare the estimated and actual labor hours for each completed project?
- 1046A building owner asks why the fire alarm ITM contract must also cover the interface relays for door release and fan shutdown. What is the best explanation?
- 1047When a building has several interconnected fire protection systems and is a high-rise, how often does the IFC require integrated testing in accordance with NFPA 4?
- 1048A department manager wants to cut costs by allowing an uncertified helper to perform the annual testing of a hospital system alone. Which NFPA 72 principle does this conflict with?
- 1049A new owner of a partly renovated building cannot find documentation for the existing system. Which step should a senior technician take first when evaluating it for a repair or replace decision?
- 1050On a large commissioning project, what is the main role of the commissioning authority (CxA)?
- 1051Under NFPA 4, who prepares the integrated system test plan that describes how interconnected fire protection and life safety systems will be tested together?
- 1052In what order do the phases of a typical fire protection commissioning process occur?
- 1053Before the integrated test of a high-rise, what should have been completed for each individual system, such as the fire alarm, sprinkler and smoke control systems?
- 1054What must the record drawings delivered at closeout reflect?
- 1055Your field crew relocated 18 strobes during construction to avoid ductwork. Who is normally responsible for showing these changes on the record drawings?
- 1056A project manager wants the field changes captured accurately for record drawings. Which practice works best?
- 1057Which of these items is normally part of the fire alarm closeout package delivered to the owner?
- 1058At substantial completion of a fire alarm project, what condition normally applies?
- 1059The specification requires owner training on the new voice evacuation system. What should the project manager deliver to show compliance?
- 1060A specification asks the contractor to turn over spare devices equal to 2 percent of each installed device type. What is this deliverable usually called?
- 1061How often must speakers and other audible notification appliances be functionally tested in an ITM program?
- 1062A smoke detector is located above a production line that can only be shut down safely during a planned plant outage. How does NFPA 72 treat testing of devices in such inaccessible areas?
- 1063An owner with a large campus wants to change some test frequencies based on documented device reliability. What does NFPA 72 allow?
- 1064A generator that complies with NFPA 110 is installed as the secondary supply for a fire alarm system. What battery capacity is still required at the control unit?
- 1065A senior PM includes 8 percent contingency in a project budget. What is the purpose of that line?
- 1066Your network shows two technicians needed in week 6 and seven in week 7 for the same project. What scheduling technique smooths these peaks within available float?
- 1067Which item should a fire alarm project manager order immediately after contract award because its lead time often controls the schedule?
- 1068Before installing devices, why must the shop drawings for a new system normally be approved?
- 1069A fire alarm system must recall elevators, close smoke dampers, release doors and shut down air handlers. Which coordination tool should be agreed with the mechanical, elevator and door hardware trades early in the project?
- 1070A company is invited to bid a design build fire alarm upgrade. What is the most important step before preparing the price?
- 1071In a proposal for a retrofit, why should the contractor list clarifications and exclusions?
- 1072Which federal law requires contractors on federally funded construction contracts over 2,000 dollars to pay locally prevailing wages?
- 1073Which federal law requires performance and payment bonds on federal construction contracts above the set threshold?
- 1074How long must an employer keep the OSHA Form 300 injury and illness log?
- 1075During which period must the OSHA Form 300A annual summary be posted in the workplace?
- 1076A technician is hospitalized as an inpatient after a fall on a job site. Within what time must the employer report this to OSHA?
- 1077A former employee left the company 18 months ago after working there for 4 years. Until when must the company keep that person's Form I-9?
- 1078A service van costs 52,000 dollars, has an estimated salvage value of 7,000 dollars and a 5 year useful life. What is the annual straight line depreciation?
- 1079A fire alarm company has 640,000 dollars in current assets and 400,000 dollars in current liabilities. What is its current ratio?
- 1080Using the same figures, 640,000 dollars of current assets and 400,000 dollars of current liabilities, what is the company's working capital?
- 1081A technician earns 34 dollars per hour. Payroll taxes, insurance and benefits add a labor burden of 40 percent. What is the burdened labor cost per hour?
- 1082The burdened labor cost is 47.60 dollars per hour, and the company wants a 32 percent gross margin on service labor. What hourly billing rate meets that target?
- 1083A multi year retrofit contract will buy most devices more than a year after bid. Which contract provision protects the contractor from large material price increases?
- 1084A department manager reports a backlog of 2.4 million dollars. What does backlog mean?
- 1085A fire alarm system is returned to service after a 2 day impairment for a control unit repair. What should happen before the impairment is closed out?
- 1086A failed smoke detector is replaced with an identical model at the same address. What test is required?
- 1087At the end of a project, what is the usual purpose of the AHJ's acceptance test?
- 1088Which role is most important for a Level IV technician acting as liaison on a multi stakeholder project?
- 1089A building owner wants proof each year that the fire alarm ITM program is being followed. Which deliverable best provides this?
- 1090When an operations manager plans staff for a campus ITM contract, why should deficiency repairs be estimated separately from routine testing?
- 1091Which factor makes a cost plus contract riskier for the owner than a lump sum contract?
- 1092A project's planned labor for rough in was 900 hours for 60 percent of the work. Actual hours spent are 1,080 for that 60 percent. What is the labor productivity factor compared with plan?
- 1093Which IBC requirement typically applies before fire alarm work begins in a new building?
- 1094A new service manager wants to measure how well the department keeps customers' systems compliant. Which indicator is most directly related?
- 1095A designer is asked to estimate total amplifier wattage for budgeting a voice system with 220 speakers tapped at 1 watt and 40 speakers tapped at 2 watts. The spec requires 25 percent spare capacity. What minimum amplifier capacity should be budgeted?
- 1096A project manager compares a bid from a subcontractor that is 30 percent below the other bids. What is the most prudent response?
- 1097Which statement about the relationship between the fire alarm contractor and the engineer of record is typically true on a design bid build project?
- 1098A project includes work in an occupied hospital. Which item should be part of the project plan before work begins?
- 1099A company plans its first ERCES installation. Before bidding, which department level decision is most important?
- 1100Which scheduling format shows each activity as a horizontal bar against a calendar, but does not clearly show the logic links between activities?
Submittals, Shop Drawings and Records
- 2001You are reviewing a fire alarm submittal before it goes to the building official. Which item does the IBC require on fire alarm shop drawings?
- 2002A submittal shows strobe locations but no candela settings. Under the IBC shop drawing requirements, how should the reviewer respond?
- 2003Under NFPA 72, which item belongs to the minimum documentation required for every new system?
- 2004Which format does NFPA 72 accept for the sequence of operation in the system documentation?
- 2005You are approving shop drawings drawn by a Level II technician. Which check is most important to confirm the drawings meet NFPA 72 documentation rules?
- 2006A reviewer stamps shop drawings with a status that lets the contractor proceed, provided the marked corrections are made, without a resubmittal. Which status is this?
- 2007A contractor submits a different manufacturer's speaker than the one in the specification as an equal. What must happen before it can be installed?
- 2008A control unit draws 1.8 A in standby and 6.5 A in alarm. Using 24 hours of standby, 5 minutes of alarm and the 1.25 aging correction factor of NFPA 72 (2022/2025), what minimum battery capacity results?
- 2009A voice evacuation panel draws 2.1 A in standby and 14 A in alarm at full connected load. Without any margin, what battery capacity is needed for 24 hours of standby followed by the required alarm duration for an emergency voice system?
- 2010A NAC uses 14 AWG solid copper with 3.07 ohms per 1,000 ft, runs 300 ft to the last appliance and carries 2.0 A, assumed lumped at the end. Starting from 20.4 V at end of battery life, what voltage is at the last appliance?
- 2011A NAC must carry 2.5 A to the end of a 400 ft run, and the voltage may drop no more than 4.4 V. Using solid copper resistances of 3.07 ohms (14 AWG), 1.93 ohms (12 AWG) and 1.21 ohms (10 AWG) per 1,000 ft, what is the smallest conductor that works?
- 2012A shop drawing shows a single wall mounted strobe in a 40 ft by 40 ft conference room. What is the minimum effective intensity for that appliance based on the NFPA 72 room spacing table?
- 2013Where must the system record documents be stored?
- 2014The documentation cabinet for a high-rise is placed in the engineering office instead of at the fire command center. What must be provided at the control unit?
- 2016How long must the record of completion and the record drawings be retained?
- 2017How long must records of a periodic inspection and test be kept under NFPA 72?
- 2018Which statement about the form of NFPA 72 records is correct?
- 2019Where must a copy of the site-specific software be kept after installation or a program change?
- 2020After a program change on an existing system, what must happen to the record documentation?
- 2021Who is responsible for completing the record of completion for a new fire alarm installation?
- 2022When a performance-based design is used for detection in an atrium, what documentation must be provided?
- 2023Why must the assumptions of a performance-based detection design be recorded and kept with the system documents?
- 2024For an emergency communication system, what must happen to the risk analysis?
- 2025Which design documents must state the pathway survivability level used for each circuit of a voice evacuation system?
- 2026A voice system design treats storage closets as not requiring intelligible voice. Where must this decision be documented?
- 2031Which item should an ITM inspection and test record include?
- 2032A technician finds that 14 smoke detectors failed sensitivity testing. How should this be documented?
- 2033Shop drawings for an addition to an existing system are under review. Which item is needed to confirm the existing power supply can support the new devices?
- 2035Which piece of information should a Level IV reviewer verify is shown on the floor plans of fire alarm shop drawings?
- 2036Shop drawings show a riser diagram but no indication of conductor type and size. Why should the reviewer return them?
- 2037Which statement describes the security of system documentation under NFPA 72?
- 2038A new control unit is installed in a lobby. Under NFPA 72 (2022/2025), what mounting limits apply to its displays, indicators and controls unless the AHJ permits otherwise?
- 2039When reviewing shop drawings, why should the reviewer compare the control unit's listed equipment with the submitted devices?
- 2040A releasing system submittal is under review. Which item is most important to include?
Complex Notification and Emergency Communication Systems
- 3001A new Group A assembly building will have an occupant load of 1,200. Which occupant notification method does the IBC require for it?
- 3002For an EVACS in a high-rise office building, which group of paging zones does the IBC require as a minimum?
- 3003Which manual control does the IBC require at an EVACS control unit?
- 3004In an ECS, a live voice announcement starts while a prerecorded evacuation message is playing in the same zone. What should happen?
- 3005What is the standard audible evacuation signal for total evacuation when no voice message is used?
- 3006A voice evacuation message is designed around an alert tone. How is the tone typically arranged with respect to the message?
- 3007Under the public mode audibility rule, what minimum sound level is required in a space with an average ambient level of 68 dBA and no loud sounds lasting 60 s or more?
- 3008A private mode notification design covers a hospital nurse station with an average ambient level of 60 dBA. What minimum signal level is required?
- 3009What is the maximum total sound pressure level permitted for audible notification at the minimum hearing distance?
- 3010A dormitory design uses audible appliances to wake sleeping occupants. What signal characteristic is required in the sleeping rooms?
- 3011In a hotel guest room, what minimum audible level is required at the pillow for the sleeping area signal?
- 3012A speaker produces 84 dBA at 10 ft on its 1 W tap. Ignoring reflections, what level would you expect at 40 ft?
- 3013A speaker produces 84 dBA at 10 ft on its 1 W tap. What would it produce at 10 ft on its 2 W tap?
- 3014Two identical speakers each produce 80 dBA at a listening point. What is the combined level?
- 3015A designer moves a speaker tap from 1 W to 1/4 W. What change in output should be expected?
- 3016A zone has 64 speakers tapped at 1 W and 20 speakers tapped at 2 W. The design adds 20 percent spare capacity. What minimum amplifier rating is needed?
- 3017A 70.7 V speaker circuit carries a total speaker load of 50 W. What current does the circuit draw?
- 3018An EVACS draws 3 A in standby and 14 A in alarm. Before any safety factor, what battery capacity is needed?
- 3019Why does a voice system need 15 minutes of alarm capacity on secondary power while a horn and strobe system needs only 5 minutes?
- 3020What is the recommended acceptance criterion for intelligibility when measured with the STI method?
- 3021What is an acoustically distinguishable space (ADS)?
- 3022During design of a voice system for a parking garage, the engineer marks the garage as an ADS where intelligibility is not required. What must still be achieved there?
- 3023A large, highly reverberant atrium fails intelligibility testing. Which design change is most likely to improve it?
- 3024Which factor most directly lowers speech intelligibility in an occupied space?
- 3025How should the average ambient sound level for an audibility design normally be determined?
- 3026In a space where the average ambient sound level is very high, the code no longer relies on audible signals alone. What is required instead?
- 3027A wall mounted strobe will cover a single 40 x 40 ft room and is centered on one wall. What minimum effective intensity is required?
- 3028In a hotel sleeping room, the strobe will be mounted 18 in. below the ceiling. What minimum effective intensity is required?
- 3029Three strobes are visible from one point in an open office. What requirement applies to them?
- 3030A corridor 12 ft wide and 210 ft long needs visible notification. What spacing rule applies to the strobes?
- 3031What flash rate range applies to visible notification appliances?
- 3032A campus requests mass notification strobes for non-fire emergencies. What color guidance applies?
- 3033What is the basis for deciding whether a building needs mass notification and how it must perform?
- 3034A university risk analysis shows that an active shooter message should take precedence over a fire evacuation signal. What does the code allow?
- 3035Which system type uses text messages, email and phone calls to reach specific people?
- 3036A military base wants voice warnings across its outdoor areas. Which ECS type fits?
- 3037In an in-building MNS, what is the role of the autonomous control unit?
- 3038What is a local operating console in an MNS?
- 3039A designer plans a combined fire alarm and MNS. What must be confirmed about the equipment?
- 3040For an in-building MNS, what secondary power duration is generally required where the system is used for emergencies?
- 3041A high-rise uses relocation rather than total evacuation. What survivability level applies to the notification circuits?
- 3042What distinguishes pathway survivability Level 3 from Level 2?
- 3043Which pathway survivability level, added in the 2022 edition, uses 1-hour protection?
- 3044Where must two-way firefighter telephone stations or jacks generally be provided in a high-rise?
- 3046What is required for a two-way communication system at an elevator landing area of refuge?
- 3047In a phased evacuation of a high-rise, which floors usually receive the evacuation signal first?
- 3048Why is a separate message often given in exit stairways during phased evacuation?
- 3049What must happen when a speaker circuit in an EVACS develops an open circuit?
- 3050A health care facility uses private mode notification in patient care areas. What does this typically mean?
- 3051A client asks for MNS messages without a script. What is the best design practice?
- 3052For a mass notification system, how should access to message initiation be controlled?
- 3053Which test is most appropriate to verify voice intelligibility at acceptance?
- 3054An existing building's voice system is being expanded with a new wing. Which design check is most important for the existing amplifiers?
- 3055In a multi-building campus, which design choice best supports a single coordinated emergency message?
Complex Detection, Integrated and Special Systems
- 4001An air sampling smoke detection system is being designed for a data center. What maximum transport time from the farthest sampling port is generally permitted?
- 4002For spacing purposes, how is each sampling port of an air sampling detection system treated?
- 4003How should an ASD pipe network design be verified before installation?
- 4004How must ASD sampling pipe be identified in the field?
- 4005An ASD system passes its calculated design but field transport time is 40 percent longer. What is the most likely cause?
- 4006A clean room has 60 air changes per hour. How does high airflow affect smoke detector spacing?
- 4007Where should smoke detectors be placed relative to supply air diffusers?
- 4008Heat detectors have a listed spacing of 50 ft. The smooth ceiling is 19 ft high. What spacing applies after the height reduction factor of 0.64?
- 4009Where should smoke detectors be placed on a peaked ceiling?
- 4010An atrium has a 90 ft ceiling and a risk of smoke stratification. Which design approach addresses this?
- 4011What does a performance-based detection design typically include?
- 4012In a building with smoke control, which panel has the highest priority over the smoke control equipment?
- 4013On a firefighter's smoke control panel, what indicator color is used to show a fan or damper fault?
- 4014Where is the firefighter's smoke control panel normally located in a high-rise?
- 4015Which listing category is required for control equipment used in smoke control systems?
- 4016What self-test feature does the IBC require for dedicated smoke control systems?
- 4017Under NFPA 92, how often must a dedicated smoke control system be operationally tested?
- 4018Why should manual pull stations generally not start zoned smoke control?
- 4019Who usually performs the required acceptance inspection of a smoke control system under the IBC?
- 4020What is a releasing service fire alarm control unit used for?
- 4021A clean agent system design calls for an abort switch. Where should it be located?
- 4022Which abort switch operation is generally recommended for clean agent systems?
- 4023What must happen when a releasing system disconnect switch is placed in the disconnect position?
- 4024A double interlock preaction system is being designed. What two events are needed to fill the piping with water?
- 4025Why is cross-zoning or counting zones used for clean agent release?
- 4026Before testing a releasing system in an occupied data center, what should the technician do?
- 4027Which statement about manual release stations for a clean agent system is correct?
- 4028Which initiating devices may normally initiate elevator Phase I recall?
- 4029A smoke detector in the elevator machine room activates. What additional signal must the elevator receive?
- 4030An elevator hoistway has sprinklers. Where must heat detectors for shunt trip be located?
- 4031A designer wants to use a waterflow switch to initiate shunt trip. What restriction applies?
- 4032What must be monitored for integrity in an elevator shunt trip circuit?
- 4033Under NFPA 72 2022, how close must the relay or interface device be to the component it controls?
- 4034Which statement about duct smoke detectors is correct?
- 4035A duct smoke detector is connected to a building fire alarm system. What signal does its activation normally initiate?
- 4036How does the IBC define a high-rise building?
- 4037What minimum size does the IBC set for a high-rise fire command center?
- 4038Which equipment must be in a high-rise fire command center?
- 4039What is a Class N pathway?
- 4040In a networked fire alarm system, what must happen if communication between nodes is lost?
- 4041In a networked campus system, what is the typical maximum time for an alarm at one node to be displayed at the main node?
- 4046What minimum signal strength does the IFC require for ERCES coverage, inbound and outbound?
- 4047What delivered audio quality is required for ERCES under the IFC?
- 4048What coverage does the IFC require in critical areas such as fire command centers, fire pump rooms and exit stairways?
- 4049What standby power duration does the IFC require for ERCES signal boosters?
- 4050In an ERCES acceptance test, each floor is divided into 20 grid areas. How many failed grid areas cause that floor to fail?
- 4051Which condition must ERCES supervision report to the fire alarm system?
- 4052Before an ERCES signal booster is installed, what approval does the IFC require besides the fire code official's?
- 4053What enclosure is generally required for ERCES signal boosters and battery systems?
- 4054An owner asks whether a new office tower needs an ERCES. What is the right first step?
- 4055How often must an ERCES be tested after acceptance under the IFC?
- 4056A fire alarm department starts a training program for new technicians. Which approach best follows adult learning principles?
- 4057How should a fire alarm company demonstrate that its technicians are qualified?
- 4058A Level IV technician wants to influence future editions of NFPA 72. What is the formal route?
- 4059A project is planned in a new jurisdiction. What step best builds a good working relationship with the AHJ?
- 4060What OSHA requirement applies when technicians may be exposed to energized circuits during testing?
All questions individually: Texas Fire Alarm License Exam
Texas Fire Alarm Law and Rules
- 1001Under Texas law, an individual or organization that plans, sells, installs, services or monitors fire alarm systems as a business must first hold
- 1002Each separate office location of a registered fire alarm firm, other than the location shown on its certificate, generally needs
- 1003Before a fire alarm registration certificate is issued, the applicant must file evidence of
- 1004Unless changed by commissioner rule, the minimum general liability limits for a registered fire alarm firm are
- 1005Each registered firm, including a single station firm, must employ at least one
- 1006To lawfully perform licensed fire alarm work in Texas, a licensee must also be
- 1007Which statement about the scope of Texas fire alarm licenses is correct?
- 1008A residential fire alarm technician may provide direct on-site supervision to a registered firm's employee
- 1009Which license authorizes installing, certifying, inspecting and servicing, but NOT planning, fire alarm systems in one- and two-family residences?
- 1010Which license is limited to single station smoke or heat detectors that are not connected to any other device or system in one- and two-family homes?
- 1011Which license allows planning fire alarm systems in commercial buildings?
- 1012An applicant for a fire alarm planning superintendent license must show technical qualification by
- 1013An applicant for a fire alarm technician license may substitute for the SFMO technical qualifying test
- 1014An applicant for a residential fire alarm technician license must provide proof of
- 1015The residential fire alarm technician training course must include at least
- 1016The examination at the end of a residential fire alarm technician course must have at least 25 questions, and passing requires at least
- 1017To be approved as a fire alarm training school instructor, an applicant must hold a qualifying license and have at least
- 1018Under Chapter 6002, participation in continuing education programs for fire alarm licensees is
- 1019A renewed fire alarm license or registration certificate is valid for
- 1020A fire alarm license that has been expired for 60 days may be renewed by paying the renewal fee plus a late fee that
- 1021A fire alarm license that has been expired for two years or longer
- 1022For an individual fire alarm technician license, the initial fee and the two-year renewal fee are
- 1023A licensee whose license is unexpired but who is not employed by a registered firm at renewal time
- 1024A registration certificate or license issued under Chapter 6002
- 1025Under the fire alarm rules, a registered firm's business location must be
- 1026A registered firm's designated employee must be
- 1027A change in a firm's designated employee must be reported in writing to the State Fire Marshal's Office within
- 1028Vehicles regularly used for fire alarm installation or service must display the company name, telephone number and certificate number in letters at least
- 1029When a fire alarm firm's ownership changes completely, the firm must
- 1030How many full-time licensed individuals must a registered firm employ at each main or branch office location?
- 1031A firm applying for a registration certificate to engage in monitoring must provide evidence of
- 1032After passing a required license test, an applicant must complete all application requirements within
- 1033A licensee who renews within two years after the license expired
- 1034A licensee who changes employers or adds a registered firm must obtain a revised license by submitting written notice and the fee within
- 1035Which activity is exempt from the Texas fire alarm licensing provisions?
- 1036An electrical contractor installing fire alarm wiring and devices during construction is exempt from licensing only if, among other conditions,
- 1037A city-licensed electrician may install which devices in a residence without a fire alarm license?
- 1038Which person is exempt from the license requirement under Chapter 6002?
- 1039An employee of a registered firm who has no fire alarm license may perform installation work when
- 1040Under the fire alarm rules, the definition of direct supervision excludes the installation of
- 1041Unlicensed employees of a registered firm who sell and install single station residential alarms under the exemption must be supervised by a
- 1042A fire detection or alarm device sold or installed in Texas must generally carry
- 1043Which is a prohibited practice under Chapter 6002?
- 1044Violating the requirement to hold a firm registration certificate or a license is a
- 1045If the state fire marshal proposes to revoke a fire alarm license, the license holder is entitled to a hearing conducted by
- 1046A person whose fire alarm license was revoked may not reapply until
- 1047A Texas city or county may require a registered fire alarm firm to
- 1048A municipality may by ordinance require a registered monitoring firm to
- 1049Every fire alarm system or modification to an existing system must be planned by
- 1050Fire alarm plans, manuals and documents under the Texas rules
- 1051For a commercial installation, instead of the record of completion in the adopted standard, the licensee generally completes
- 1052A copy of a completed installation certificate must be sent to the local AHJ within
- 1053The certifying company must keep its copy of the installation certificate for
- 1054Which is one of the three required installation inspections by the licensed firm?
- 1055If corrective action from an installation inspection is not started within ten calendar days, the registered firm must
- 1056The installation label for a new fire alarm system must be
- 1057Which label must NOT be attached for the installation of a new system?
- 1058Which signature is NOT acceptable on Texas fire alarm labels?
- 1059After any service on a fire alarm system, the licensee must attach a
- 1060Service labels must remain in place for at least
- 1061What color is the Texas inspection/test label?
- 1062Inspection/test labels must remain in place for at least
- 1063For a new installation, an inspection/test label may be applied
- 1064A yellow label is attached when a system
- 1065Where must a yellow or red label be attached?
- 1066After attaching a yellow label, the licensee or firm must give written notice to the owner and the local AHJ within
- 1067A red label is attached when a system or part of it
- 1068When a red label is attached because a system is inoperable, the licensee must
- 1069When a red label is attached for a fault condition or impairment (not a fully inoperable system), written notice must be given within
- 1070During a service call a technician finds that the system did not comply with the standards adopted when it was installed. The technician must
- 1071A registered firm must keep complete records of all service, maintenance and testing on a system for at least
- 1072A Texas registered firm may monitor a fire alarm system located in Texas for
- 1073At a central station operated by a registered firm, which personnel requirement applies?
- 1074When a monitoring firm reports an alarm to a municipal emergency services center, which information must it provide at a minimum?
- 1075If monitoring service for a commercial property is discontinued before the contract ends, the monitoring firm must notify the owner and AHJ at least
- 1076Replacing a failed device in the same location with a listed, compatible device of similar characteristics, as determined by a planning superintendent, is treated as
- 1077When a building owner asks a registered firm for the system passwords, the firm
- 1078Under the Texas rules, planning and installation may follow an edition of a standard other than the edition adopted in 34.607 when
- 1079Which edition of NFPA 72 is adopted by the Texas fire alarm rules effective September 1, 2023?
- 1080If installation or service of a fire alarm system also includes work on part of a sprinkler or fire extinguisher system,
- 1081The licensee who attaches a service or inspection label must be licensed under the ACR number of
- 1082Which statement about planning and installation by different firms is correct under the Texas rules?
- 1083Before certifying a new installation, the certifying licensee of the installing firm must
Texas Technician Technical Knowledge (NFPA 72-2019)
- 2001For a protected premises fire alarm system, NFPA 72 requires secondary power capable of operating the system in quiescent load for
- 2002A fire alarm panel draws 0.45 A in standby and 2.8 A in alarm. Using 24 hours standby, 5 minutes alarm and the 20 percent safety margin required by NFPA 72 (2019), the minimum battery is about
- 2003An emergency voice/alarm communications system requires secondary power for 24 hours standby followed by how many minutes of alarm at maximum connected load?
- 2004A notification appliance circuit carries 1.5 A to the last appliance 400 ft from the panel on 14 AWG solid copper (about 3.07 ohms per 1,000 ft). The approximate voltage drop is
- 2005A 24 VDC initiating device circuit ends in a 4,700 ohm end-of-line resistor. The supervisory current through the resistor is about
- 2006Six strobes each draw 0.12 A and four horn/strobes each draw 0.16 A on one NAC. The total alarm current is
- 2007For public mode audible signaling, the evacuation signal should exceed the average ambient sound level by at least
- 2008A room has an average ambient sound level of 62 dBA. Under the public mode rule based on average ambient, the minimum audible signal level is
- 2009For private mode audible signaling, the signal must be at least how many dB above the average ambient sound level?
- 2010The total sound pressure level produced by audible notification appliances, measured at the minimum hearing distance, must not exceed
- 2011Audible appliances intended to awaken occupants in sleeping areas must produce a signal of at least 15 dB above average ambient, 5 dB above the maximum 60-second level, or
- 2012Audible appliances provided for sleeping areas to awaken occupants must produce a low-frequency signal with a fundamental frequency of
- 2013The standard audible emergency evacuation signal is the
- 2014In the three-pulse temporal pattern, each cycle consists of three 0.5-second on phases separated by 0.5-second off phases, followed by
- 2015Wall-mounted visible notification appliances must be installed so the entire lens is between
- 2016The flash rate of visible notification appliances must be
- 2017When more than two visible notification appliances are in any field of view, they must
- 2018In a sleeping room, a wall-mounted visible appliance with the top of its lens less than 24 inches below the ceiling must have a minimum rating of
- 2019On a smooth ceiling, spot-type smoke detectors are permitted a nominal spacing of
- 2020A spot-type smoke detector mounted on a sidewall must be located
- 2021Spot-type heat detectors on a smooth ceiling must be located so that all points on the ceiling are within what distance of a detector?
- 2022A heat detector has a listed spacing of 50 ft. On a smooth flat ceiling, the maximum distance from the detector to a wall is
- 2023Spot-type heat detectors mounted on a sidewall must be located
- 2024For ceilings higher than 10 feet, the listed spacing of spot-type heat detectors must be
- 2025NFPA 72 guidance on placing spot-type smoke detectors says to keep them out of direct airflow and at least how far from an air supply diffuser or return opening?
- 2026Duct smoke detectors used for HVAC control
- 2027Under the adopted NFPA 90A, smoke detectors in the supply air system are required downstream of filters and ahead of branch connections in air distribution systems over
- 2028The operable part of a manual fire alarm box must be mounted
- 2029Manual fire alarm boxes must be located within 5 feet of each exit doorway on each floor, and the travel distance to the nearest box must not exceed
- 2030How often must spot-type smoke detectors receive a functional test after acceptance?
- 2031Smoke detector sensitivity must be checked within one year after installation and then
- 2032Sprinkler waterflow alarm-initiating devices and valve supervisory switches are tested at what frequency under NFPA 72?
- 2033When performing the functional test of a smoke detector, the technician should
- 2034After a modification to an existing system, reacceptance testing must include all affected devices plus
- 2035Nonrestorable fixed-temperature spot-type heat detectors that have been in service for 15 years must be
- 2036Under NFPA 72, records of inspection, testing and maintenance must be kept
- 2037A circuit that keeps operating to all devices after a single open, and also after a single ground fault or wire-to-wire short, is classified as
- 2038A Class B initiating device circuit with a single open conductor will
- 2039Pathway survivability Level 2 is generally provided by
- 2040At the control unit, an alarm signal from an initiating device must cause notification appliances to activate within
- 2041Sprinkler waterflow alarm-initiating devices must initiate an alarm signal within how long after flow equal to a single sprinkler of the smallest orifice?
- 2042Heat detectors used to initiate elevator shunt trip must be located
- 2043A central station must retransmit a fire alarm signal to the communications center within
- 2044Under NFPA 70 Article 760, the branch circuit disconnecting means for fire alarm equipment must be
- 2045Which cable type is required for power-limited fire alarm circuits installed in a plenum without a raceway?
- 2046Power-limited fire alarm circuit conductors may NOT be placed in the same raceway with
- 2047How often are restorable spot-type heat detectors functionally tested after acceptance?
- 2048A nonrestorable fixed-temperature spot-type heat detector is tested in service by
- 2049A projected beam smoke detector is functionally tested by
- 2050Where alarm verification is used for smoke detectors, the verification feature must not delay the reporting of an alarm by more than
- 2051Under positive alarm sequence, trained staff must acknowledge the alarm signal within
- 2052On a peaked ceiling, a row of spot-type smoke detectors must be located on or near the peak, within what horizontal distance of the peak?
- 2053Which smoke detector type generally responds faster to slow, smoldering fires that produce large visible particles?
- 2054Ionization smoke detectors are generally most responsive to
- 2055A rate-of-rise heat detector typically operates when the temperature rises faster than about
- 2056Under the heat detector temperature classification table, an intermediate classification detector (175 to 249 degrees F) carries what color code?
- 2057The temperature rating of a fixed-temperature heat detector must be at least how much above the maximum expected ambient ceiling temperature?
- 2058Unless the AHJ permits otherwise, manual fire alarm boxes must be
- 2059A double-action manual fire alarm box requires the user to
- 2060A single open in a Class B notification appliance circuit causes
- 2061A conventional (non-addressable) initiating device circuit in normal condition reads a wire-to-wire short at the panel as
- 2062A wire-to-wire short on a supervised notification appliance circuit normally causes
- 2063Polarized notification appliances on a supervised NAC allow the control unit to
- 2064A panel shows a ground fault trouble. A common first step to locate it is to
- 2065With an IDC disconnected from the panel, an ohmmeter across the loop reads infinite resistance. This indicates
- 2066Disconnected from the panel, a healthy Class B IDC with a 4.7 kilohm EOL resistor should read approximately
- 2067To measure the current drawn by a notification appliance circuit with a standard multimeter, the meter must be connected
- 2068Under Article 760, which cable type may be used as a substitute for type FPLR riser cable?
- 2069Article 760 requires exposed fire alarm cables to be
- 2070The branch circuit supplying fire alarm equipment must NOT be
- 2071For NPLFA circuits, 18 AWG conductors must have overcurrent protection not exceeding
- 2072The minimum conductor size permitted for non-power-limited fire alarm circuits in a multiconductor cable is
- 2073When fire alarm cables pass through a fire-rated wall, the penetration must be
- 2074Circuit integrity (CI) cable is designed to
- 2075During an acceptance test of a new fire alarm system, the share of devices and circuits that must be tested is
- 2076Smoke detectors in elevator lobbies used for elevator recall are intended to
- 2077If the elevator lobby detector on the designated recall level activates, the cars recall to
- 2078Activation of a detector in the elevator machine room or hoistway must also cause
- 2079Where a duct smoke detector is connected to a fire alarm system and area detection is present, its activation generally initiates
- 2080A valve supervisory switch must signal off-normal within two revolutions of the handwheel or when the valve stem moves
- 2081Supervisory signals at the control unit must be
- 2082A digital alarm communicator transmitter (DACT) must send a test signal to the receiver at least
- 2083A DACT must be connected to
- 2084The main difference between a smoke alarm and a smoke detector is that a smoke alarm
- 2085Fire alarm system batteries must be marked with
- 2086Primary power for a protected premises fire alarm system is generally supplied by
- 2087The location of the fire alarm branch circuit disconnecting means must be
- 2088A listed relay or control module used for an emergency control function must be located within what distance of the controlled component?
- 2089After acceptance of a new system, the document that summarizes the system and its testing is the
All questions individually: Ohio Fire Alarm Certification Exam
Ohio Law, Certification and Fire Code
- 1001Who issues the certificate an individual needs in Ohio to service, test, repair or install fire alarm and detection equipment for profit?
- 1002What minimum score must a non-provisional applicant reach on the State Fire Marshal fire protection installer examination?
- 1003Which applicant may receive Ohio fire protection certification without passing the installer examination?
- 1004How many provisional certificate holders may one certified individual directly supervise at the same time?
- 1005What must a certified individual do with the state certificate while performing fire alarm work for profit?
- 1006What is the State Fire Marshal application fee for an original individual certification?
- 1007What is the renewal fee for an individual fire protection certification in Ohio?
- 1008An individual certificate holder's last name is Keller. On which date does the certification expire each year?
- 1009A fire alarm technician's renewal application reaches the State Fire Marshal after the expiration date. What happens?
- 1010A technician works as a sole proprietor under her own name. What certification does the Ohio Fire Code require?
- 1011What minimum liability insurance or bonding must a company show to obtain Ohio fire protection company certification?
- 1012Within what time must a certified individual notify the State Fire Marshal in writing of a change of primary mailing or email address?
- 1013An individual's certification has been revoked. When may that person apply again?
- 1014Which of the following is a listed cause for the State Fire Marshal to suspend or revoke a certificate?
- 1015Under the Ohio Revised Code, what is the penalty class for servicing or installing fire protection equipment for profit without the required certificate?
- 1016Which item must appear on the annual inspection tag that the Ohio Fire Code requires on a fire protection system?
- 1017Where should the Ohio annual inspection tag be attached on a fire alarm system?
- 1018How much advance notice must the responsible person give the fire code official before a scheduled acceptance test of a fire protection system in Ohio?
- 1019How long must the initial records of a fire protection system (installer, component types, manufacturers, locations) be kept?
- 1020Supervisory service for a building is being terminated. Who must notify the local fire code official, and how fast?
- 1021A required fire alarm system goes out of service. What does the Ohio Fire Code require?
- 1022When a fire alarm system or part of it is removed from service, where must the out of service tag be posted?
- 1023After a successful Ohio acceptance test, the owner wants to change how alarm signals reach the monitoring station. What is required?
- 1024Fire alarm devices are inaccessible for safety reasons during normal operations. What testing interval does the Ohio Fire Code allow?
- 1025Which of the following is exempt from supervising station monitoring under OFC 907.6.6?
- 1026How is the Ohio State Fire Marshal fire alarm and detection equipment certification exam given?
- 1027Under the Ohio Fire Code, what is the maximum floor area of a single fire alarm zone?
- 1028A duct smoke detector connected to the building fire alarm system activates. What signal does the Ohio Fire Code call for?
- 1029What fee does the Ohio Fire Code set for a duplicate individual certificate?
- 1030A certified fire protection company changes its business name. What must it do?
- 1031What is the State Fire Marshal fee for an original fire protection company certification?
- 1032The State Fire Marshal learns that an applicant installed fire alarm systems for profit without certification last year. What may the SFM do?
- 1033A building has a fire alarm system that the code does not require. What does the Ohio Fire Code say about it?
Fundamentals, Definitions and Documentation
- 2001What document verifies that a new fire alarm system was installed and tested in line with the approved plans and NFPA 72?
- 2002How long must records of fire alarm inspection, testing and maintenance be kept under NFPA 72?
- 2003A sprinkler control valve on a monitored system is partly closed. Which signal should the fire alarm system produce?
- 2004An open circuit occurs on an initiating device circuit. Which signal should the control unit display?
- 2005Under NFPA 72, who is responsible for the inspection, testing and maintenance of a fire alarm system?
- 2006Which of the following is an accepted way to qualify a person for fire alarm inspection, testing and maintenance under NFPA 72?
- 2007Before testing a monitored fire alarm system, whom should the technician notify?
- 2008A required fire alarm system will be impaired for more than how long in a 24 hour period before the AHJ must be notified and mitigation such as a fire watch provided?
- 2009When fire alarm record documents are kept in a cabinet, how must the cabinet be labeled?
- 2010In NFPA 72, what does the term approved mean?
- 2011In NFPA 72, what is the authority having jurisdiction (AHJ)?
- 2012What does the term listed mean in NFPA 72?
- 2013In NFPA 72, what is the difference between shall and should?
- 2014What is the status of the annex material in NFPA 72?
- 2015Does a new edition of NFPA 72 automatically apply to systems installed before it took effect?
- 2016Which of the following is an emergency control function of a fire alarm system?
- 2017Alarm verification may be used with which type of initiating device?
- 2018Which item belongs on fire alarm shop drawings submitted for review?
- 2019What do record drawings (as built drawings) show for a fire alarm system?
- 2020Where must a copy of site specific software be kept?
- 2021When an alarm, a supervisory and a trouble condition happen at the same time, which signal takes priority on a fire alarm system?
- 2022An existing fire alarm system is modified. What must happen with the record of completion?
- 2023What does NFPA 72 require of equipment installed in a fire alarm system?
- 2024Two wire smoke detectors are being added to an existing control unit. What must be confirmed?
- 2025Which person meets an NFPA 72 qualification route for preparing fire alarm system plans?
Circuits, Power Supplies and Control Units
- 3001For a non-voice fire alarm system, what secondary power capacity does NFPA 72 require?
- 3002What alarm duration must the secondary power of an in-building emergency voice/alarm communication system support after 24 hours of standby?
- 3003A panel draws 0.5 A in standby and 3 A in alarm. Using 24 hours standby and 5 minutes alarm, what is the required capacity before any safety margin?
- 3004A battery calculation gives 10 ampere hours. NFPA 72 (2022) requires an aging correction factor of 1.25. What battery capacity is needed at minimum?
- 3005A notification circuit draws 2 A and the total resistance of both conductors is 1.5 ohms. What is the voltage drop on the circuit?
- 3006Which marking does NFPA 72 require on the circuit disconnecting means for the fire alarm branch circuit?
- 3007What information about the primary power supply must be identified at the fire alarm control unit?
- 3008What describes a Class A pathway?
- 3009Which pathway class keeps operating through a single open, a single ground fault and a wire to wire short?
- 3010An open occurs in the middle of a Class B initiating device circuit. What is the result?
- 3011What does pathway survivability Level 2 generally require?
- 3012A ground fault develops on a monitored fire alarm pathway. What must the system do?
- 3013What is the purpose of an end of line resistor on a conventional initiating device circuit?
- 3014Which article of NFPA 70 (National Electrical Code) covers the wiring of fire alarm systems?
- 3015A trouble signal is silenced at the control unit but the fault is not fixed. What must happen?
- 3016From what source must the primary power for a fire alarm system come?
- 3017A panel draws 0.25 A in standby and 1.2 A in alarm. With 24 hours standby and 5 minutes alarm, what capacity is needed before margin?
- 3018A voice system draws 1 A in standby and 4 A in alarm. With 24 hours standby and 15 minutes alarm, what capacity is needed before margin?
- 3019A notification circuit runs 500 feet out to the last appliance. The wire has 2 ohms per 1,000 feet. What is the total loop resistance?
- 3020A 24 V notification circuit has a 3 V drop. What percentage of the supply voltage is lost?
- 3021Why do notification circuit voltage drop calculations often start from 20.4 V instead of 24 V?
- 3022A 24 V notification circuit carries 2 A. How much power does it deliver?
- 3023Ten strobes on one circuit each draw 0.1 A. What is the total circuit current?
- 3024Which wiring method is not allowed on a supervised initiating device circuit?
- 3025How must the outgoing and return conductors of a Class A pathway generally be routed?
- 3026Which pathway class was added to NFPA 72 for Ethernet network infrastructure?
- 3027Under NEC Article 760, how far must power limited fire alarm cables generally be kept from electric light and power conductors?
- 3028Which power limited fire alarm cable type is listed for use in plenums?
- 3029The fire alarm control unit is in an area that is not continuously occupied. What does NFPA 72 require at that location?
- 3030What is the main feature of a Class C pathway?
Initiating Devices
- 4001Spot type smoke detectors on a smooth flat ceiling have no listed spacing. What nominal spacing does NFPA 72 permit?
- 4002Using a 30 foot nominal spacing for smoke detectors, every point on the ceiling must be within what distance of a detector?
- 4003A spot type smoke detector is mounted on a sidewall. Where must the top of the detector be?
- 4004A heat detector has a listed spacing of 50 feet. What is the maximum distance from the detector to a wall?
- 4005On a peaked ceiling, where must a row of spot type detectors be placed relative to the peak?
- 4006How does NFPA 72 relate the temperature rating of a fixed temperature heat detector to the ceiling temperature?
- 4007A fixed temperature heat detector is rated at 200 degrees F. Which classification and color code apply?
- 4008Above what ceiling height does NFPA 72 require heat detector spacing to be reduced?
- 4009At what height must the operable part of a manual fire alarm box be mounted?
- 4010Where must a manual fire alarm box be located relative to an exit door?
- 4011What is the maximum horizontal travel distance on the same floor to the nearest manual fire alarm box?
- 4012Within what time must a waterflow switch produce an alarm signal after flow equal to the smallest sprinkler starts?
- 4013A valve supervisory switch on an OS&Y valve must signal by what point of valve operation?
- 4014May duct smoke detectors be used in place of open area smoke detection?
- 4015In an elevator machine room with sprinklers, heat detectors used to shut down elevator power must be placed where?
- 4016How close may a spot type smoke detector be to an air supply diffuser?
- 4017A spot type smoke detector is mounted on the ceiling near a wall. What minimum distance from the wall applies?
- 4018What condition does a rate of rise heat detector respond to?
- 4019What is a rate compensation heat detector designed to do?
- 4020Which detectors normally start Phase I emergency recall of an elevator?
- 4021The elevator lobby smoke detector on the designated recall level activates. Where should the elevators go?
- 4022What happens in the elevator car when a machine room or hoistway smoke detector activates?
- 4023Which statement compares photoelectric and ionization smoke detectors correctly?
- 4024What is the maximum air sample transport time from the farthest sampling port of an air sampling smoke detection system?
- 4025Why do vane type waterflow switches usually have an adjustable retard?
- 4026Exits are grouped in an opening wider than 40 feet. Where must manual fire alarm boxes be placed?
- 4027When should smoke detectors be installed in a building under construction?
Notification Appliances
- 5001In public mode, how far above the average ambient sound level must audible alarm signals be?
- 5002What maximum sound pressure level must audible notification not exceed at the minimum hearing distance?
- 5003In private mode, how far above the average ambient sound level must audible signals be?
- 5004What is the minimum audible signal level at the pillow in a sleeping area, when no higher value results from the ambient sound?
- 5005Which audible signal is required to wake occupants in sleeping rooms of Group R-1 and R-2 when a fire alarm system is required?
- 5006What is the standard audible evacuation signal pattern required by NFPA 72?
- 5007At what height must a wall mounted visible notification appliance be installed?
- 5008When must visible notification appliances in a room be synchronized?
- 5009What flash rate must visible notification appliances have?
- 5010A horn produces 90 dBA at 10 feet. About what level can be expected at 20 feet in free field conditions?
- 5011Two horns each produce 80 dBA at a point. About what is the combined sound level there?
- 5012In a sleeping room, a visible appliance is mounted within 24 inches of the ceiling. What minimum effective intensity is required?
- 5013Using the room spacing table, what minimum strobe intensity is needed for one wall mounted strobe in a 30 by 30 foot room?
- 5014Using the room spacing table, what minimum strobe intensity is needed for one wall mounted strobe in a 40 by 40 foot room?
- 5015In a corridor 20 feet wide or less, how far from each end may the first visible appliance be?
- 5016What is the maximum spacing between visible appliances in a corridor 20 feet wide or less?
- 5017Where is private mode notification typically used?
- 5018How is the average ambient sound level measured for audibility design?
- 5019At what height above the floor is audible signal sound pressure normally measured?
- 5020A horn produces 96 dBA at 10 feet. About what level can be expected at 40 feet in free field conditions?
- 5021How long does one complete cycle of the three pulse temporal pattern take?
- 5022Which audible pattern is used for carbon monoxide alarm signals?
- 5023What light color must visible notification appliances used for fire alarm signaling have?
- 5024In a sleeping room, how far from the pillow may the visible notification appliance be?
Inspection, Testing and Maintenance
- 6001How often must spot type smoke detectors be functionally tested under NFPA 72?
- 6002When must the first sensitivity test of a smoke detector be performed after installation?
- 6003After the second required sensitivity test, a detector has stayed within its listed range. To what maximum may the interval be extended?
- 6004Which method may not be used to measure smoke detector sensitivity?
- 6005When must single and multiple station smoke alarms be replaced?
- 6006Non restorable fixed temperature spot type heat detectors have been in service for 15 years. What does NFPA 72 require?
- 6007How are restorable spot type heat detectors functionally tested?
- 6008How is a non restorable fixed temperature heat detector tested in the field?
- 6009How often must manual fire alarm boxes be tested?
- 6010How often must audible and visible notification appliances be tested under NFPA 72?
- 6011How often must sprinkler waterflow alarm devices connected to the fire alarm system be tested?
- 6012After a software change, which devices must be tested in a reacceptance test?
- 6013What marking does NFPA 72 require on batteries used for fire alarm secondary power?
- 6014How often must the control equipment of a fire alarm system that is monitored for alarm, supervisory and trouble signals be visually inspected?
- 6015How many devices must be tested during the initial acceptance test of a new fire alarm system?
- 6016Why is a magnet test alone not enough for a functional test of a smoke detector?
- 6017What must be verified when testing a duct smoke detector with sampling tubes?
- 6018Which item must an NFPA 72 inspection and test report include?
- 6019A defect found during inspection is not corrected by the end of the visit. What should the technician do?
- 6020How often must a household fire alarm system with a control unit be tested by a qualified technician?
- 6021A smoke detector's measured sensitivity is outside its listed range. What must be done?
- 6022Testing of a monitored system is complete. What must the technician do before leaving?
- 6023An engine driven generator serves as secondary power for a fire alarm system. Which standard governs its maintenance and testing?
- 6024How is a sprinkler waterflow switch normally tested on a wet pipe system?
- 6025During the annual test of secondary power, what is done?
- 6026A building has 300 non restorable spot type heat detectors that are 15 years old. How many must go to a lab if the owner does not replace them all?
- 6027What is a visual inspection of fire alarm devices meant to find?
- 6028When must valve regulated lead acid (VRLA) batteries in a fire alarm system be replaced at the latest?
Supervising Stations, Signaling and Household Warning
- 7001Under positive alarm sequence, within what time must trained staff acknowledge an automatic detector alarm?
- 7002Under positive alarm sequence, how much investigation time is allowed after acknowledgment?
- 7003Within what time must a supervising station retransmit an alarm signal to the communications center?
- 7004In a dwelling unit, where does NFPA 72 require smoke alarms?
- 7005Smoke alarms in new dwelling units are interconnected. What must happen when one alarm activates?
- 7006How far must a smoke alarm be kept, measured horizontally, from the door of a bathroom that contains a shower or tub?
- 7007Which type of supervising station is owned and operated by the same entity that owns the protected property?
- 7008A digital alarm communicator transmitter (DACT) sends signals to a supervising station. What does NFPA 72 require for its connection?
- 7009What must a central station be for central station service under NFPA 72?
- 7010For central station service, how soon must a runner arrive at the property when one is dispatched for a supervisory signal?
- 7011Whom must a supervising station notify when it receives a supervisory signal?
- 7012When is a remote supervising station typically used?
- 7013In NFPA 72, what is a communications center?
- 7014A manual fire alarm box is pulled in a building that uses positive alarm sequence. What happens?
- 7015How must smoke alarms in new dwelling units be powered?
- 7016A household smoke alarm is mounted on a wall. Where must its top be?
All questions individually: Oklahoma Fire Alarm Technician Exam
Oklahoma Alarm Act and ODOL Rules
- 1001Under the Oklahoma rules, what must every fire alarm company employ?
- 1002A fire alarm company's manager leaves the company. What must the company do?
- 1003Who must be on site whenever fire alarm work is being performed in Oklahoma?
- 1004What is the maximum number of technician or salesperson trainees per fire alarm manager or technician on a job site?
- 1005Within what time after being hired must a fire alarm technician trainee submit a trainee application to ODOL?
- 1006What experience must an applicant document for an Oklahoma fire alarm manager license?
- 1007A technician wants to work on residential fire alarm systems in Oklahoma. Which additional license does the rule require?
- 1008A company holds only a residential fire alarm company license. Where may it work?
- 1009When does an individual Oklahoma fire alarm technician license expire?
- 1010A technician renews 45 days after the license expired. What fee applies?
- 1011A license has been expired for more than two years. What must the person do to work again?
- 1012Within how many days must an individual licensee notify ODOL of a change of employer or home address?
- 1013How must the company license number be shown on vehicles that display the company name?
- 1014What must a licensed fire alarm technician carry while working?
- 1015What is the criminal penalty for violating the Alarm, Locksmith and Fire Sprinkler Industry Act?
- 1016What is the maximum administrative fine per violation that the Commissioner of Labor may impose after a hearing, and the overall cap?
- 1017After an annual inspection, a yellow tag is placed on a commercial fire alarm system. What notice is required?
- 1018A commercial fire alarm system is found inoperable and red tagged. How soon must the owner and fire code official be notified in writing?
- 1019Who may remove the white installation tag from a commercial fire alarm control panel?
- 1020After repairing deficiencies found at an annual inspection and applying a green deficiency repair tag, when must the repair document go to the AHJ?
- 1021A consumer cancels a monitoring contract on customer owned fire alarm equipment and asks for the system to be released. What must the company do?
- 1022If a conflict exists between an adopted NFPA standard and the ODOL alarm rules chapter, which applies?
Basic Electronics and Calculations
- 2001A system draws 0.4 A in standby and 2.4 A in alarm. Ignoring any safety margin, what battery capacity is needed for 24 hours standby plus 5 minutes alarm?
- 2002Standby load is 0.25 A and alarm load is 3.0 A. Under NFPA 72 (2016) the designer applies the 20 percent safety margin, with 24 hours standby and 5 minutes alarm. What is the minimum battery size?
- 2003A notification appliance circuit carries 1.5 A. Each conductor is 250 ft long and the wire resistance is 2.0 ohms per 1,000 ft. What is the voltage drop on the circuit?
- 2004An initiating device circuit has a 24 V supply and a 4,700 ohm end of line resistor. Ignoring wire resistance, what supervisory current flows?
- 2005A technician finds a ground fault trouble on the panel. What is the most likely cause?
- 2006A 24 VDC notification circuit draws 2.5 A. What power does it consume?
- 2007Resistors of 100, 220 and 330 ohms are connected in series. What is the total resistance?
- 2008Two 100 ohm resistors are connected in parallel. What is the equivalent resistance?
- 2009How must a multimeter be connected to measure the current drawn by a notification circuit?
- 2010What is the state of a normally open relay contact when the relay coil is not energized?
- 2011Which precaution protects fire alarm circuit boards from static electricity damage during service?
- 2012Which statement about American Wire Gauge sizes is correct?
- 2013A 24 V circuit has a total resistance of 12 ohms. What current flows?
- 2014A device draws 0.05 A at 24 V. What is its effective resistance?
- 2015A transformer is rated 40 VA at a 24 V secondary. What is the maximum secondary current?
- 2016A current of 0.1 A flows through a 100 ohm resistor. How much power does the resistor dissipate?
- 2017Two 12 V, 7 Ah batteries are connected in series. What is the result?
- 2018Two 12 V, 7 Ah batteries are connected in parallel. What is the result?
- 2019A transformer reduces 120 V on the primary to 24 V on the secondary. What is its turns ratio?
- 2020How does a ground loop usually occur in a low voltage signal circuit?
- 2021What must be done before measuring resistance with a multimeter?
- 2022How is a multimeter connected to measure the voltage across a notification appliance?
- 2023A resistor has bands of brown, black and red. What is its value?
- 2024What does a diode do in a DC circuit?
System Layout and NFPA 72 Requirements
- 3001What is the nominal spacing used for spot-type smoke detectors on a smooth, flat ceiling when no other spacing is required by the manufacturer?
- 3002A spot-type smoke detector is to be mounted on a sidewall instead of the ceiling. Where must the top of the detector be?
- 3003A spot-type heat detector is mounted on a sidewall. What mounting zone is permitted?
- 3004A heat detector has a listed spacing of 50 ft. What is the maximum distance from a wall to the nearest detector on a smooth ceiling?
- 3005A heat detector with a listed spacing of 50 ft is installed on a smooth ceiling 15 ft high. Using the ceiling height reduction factor of 0.77 for ceilings over 14 ft up to 16 ft, what is the adjusted spacing?
- 3006On a solid joist ceiling, how is heat detector spacing measured at right angles to the joists adjusted?
- 3007Under a peaked ceiling, where must a row of spot-type smoke detectors be placed?
- 3008A heat detector should have a temperature rating at least how far above the maximum expected ambient ceiling temperature?
- 3009A heat detector frame is colored white. Which temperature classification does this color code indicate?
- 3010NFPA 72 guidance on locating a smoke detector near an air supply diffuser calls for what minimum separation?
- 3011What is the primary purpose of a duct smoke detector in an HVAC system?
- 3012What is the required mounting height for the operable part of a manual fire alarm box?
- 3013A manual fire alarm box serves an exit doorway. Within what distance of the doorway must it be located?
- 3014What is the minimum sound level for an audible public mode evacuation signal in an area with an average ambient sound level of 70 dBA?
- 3015What is the maximum sound pressure level permitted for an audible notification appliance at the minimum hearing distance?
- 3016A sleeping room has an average ambient of 35 dBA and a maximum 60 second level of 45 dBA. What is the minimum required audible signal level at the pillow?
- 3017What signal characteristic does NFPA 72 require for audible alarms intended to wake sleeping occupants in sleeping areas?
- 3018Which signal pattern is required for the standard fire evacuation tone?
- 3019A notification appliance rated at 85 dBA at 10 ft is heard at 20 ft in a free field. Approximately what level reaches the listener at 20 ft?
- 3020Two identical horns each produce 80 dBA at a point. What is the approximate combined level at that point?
- 3021What is the permitted mounting height for wall-mounted visible notification appliances?
- 3022When must visible notification appliances in a room be synchronized?
- 3023Using the room spacing table for a single wall-mounted strobe, what minimum effective intensity is required for a 20 ft by 20 ft room?
- 3024A sleeping room strobe is mounted 18 in below the ceiling. What minimum effective intensity is required?
- 3025In a corridor not more than 20 ft wide, what is the maximum distance from the end of the corridor to the nearest visible appliance?
- 3026What is the minimum secondary power capacity for a protected premises fire alarm system without voice evacuation?
- 3027A fire alarm control unit is in an area that is not continuously occupied. What does NFPA 72 require at that location?
- 3028Within what time after an initiating device activates must the fire alarm control unit activate the alarm notification appliances?
- 3029What is the maximum time permitted for alarm verification on a smoke detector circuit?
- 3030Under positive alarm sequence, how long does trained staff have to acknowledge the alarm at the control unit?
- 3031A waterflow alarm initiating device must produce an alarm signal within what time after flow equal to one sprinkler starts?
- 3032A valve supervisory switch must signal an off normal condition within what movement of the valve?
- 3033For elevator shunt trip, where must heat detectors be located relative to sprinklers in the elevator machine room or hoistway?
Installation, Wiring and Pathways
- 4001Why should smoke detectors generally not be installed until after construction cleanup is complete?
- 4002What distinguishes a Class A pathway from a Class B pathway?
- 4003What does a Class X pathway add compared with a Class A pathway?
- 4004Which pathway class designation covers Ethernet type networks with a redundant pathway monitoring arrangement for fire alarm communication?
- 4005A survivability Level 2 pathway requires which type of protection?
- 4006Which NFPA 70 article governs fire alarm system wiring?
- 4007Power limited fire alarm cable run vertically in a shaft between floors must at least be which type?
- 4008How must the branch circuit disconnecting means for a fire alarm control unit be marked?
- 4009Two wire smoke detectors powered from an initiating device circuit must meet which requirement?
- 4010On a conventional Class B initiating device circuit, a T-tap is added to reach an extra detector. What problem does this create?
- 4011How must power limited fire alarm cable above a suspended ceiling be supported?
- 4012May power limited fire alarm conductors share a raceway with 120 V branch circuit conductors?
- 4013What makes a fire alarm circuit a power limited fire alarm (PLFA) circuit?
- 4014Fire alarm cable is installed in a ceiling space used for environmental air (a plenum). Which cable type is required?
- 4015Which communications cable type may be substituted for FPLR riser cable?
- 4016What is the minimum conductor size permitted in a multiconductor power limited fire alarm cable?
- 4017What is the main purpose of the equipment grounding conductor connected to a fire alarm control unit?
- 4018Which NEC section requires electrical equipment to be installed in a neat and workmanlike manner?
- 4019According to Article 90, what is the purpose of the NEC?
- 4020Fire alarm cable passes through a 1 hour fire rated wall. What must be done with the opening?
- 4021What does the NEC require for accessible portions of abandoned fire alarm cable?
- 4022What is the maximum conduit fill for three or more conductors in a raceway?
- 4023A shielded cable is used for a signaling line circuit. How should the drain or shield normally be connected?
- 4024How must the outgoing and return conductors of a Class A circuit generally be routed?
- 4025On a Class B initiating circuit, how should conductors be landed on a detector base?
- 4026What is the purpose of short circuit isolation modules on an addressable signaling line circuit?
- 4027After installation, which drawings must show the actual field locations of devices and wiring?
- 4028Which document defines what each initiating device must cause the system to do, such as recall elevators or release doors?
- 4029At acceptance, what should the installer give the owner as part of customer training?
- 4030Why are horns and strobes on a Class B notification circuit polarized?
- 4031Where is the end of line resistor installed on a Class B notification appliance circuit?
- 4032How must EMT be supported in relation to outlet boxes?
- 4033Where must splices in fire alarm conductors be made?
- 4034A cable runs through holes bored in wood studs. When must a steel plate protect it?
- 4035Non power limited fire alarm (NPLFA) circuits must be installed using which wiring methods?
Inspection, Testing and Service
- 5001What is the required frequency for functional testing of system smoke detectors?
- 5002When must the first sensitivity test of a system smoke detector be performed?
- 5003Which method is NOT acceptable to measure the sensitivity of a smoke detector?
- 5004Nonrestorable fixed temperature spot-type heat detectors have been in service for 15 years. What does NFPA 72 require?
- 5005How should a restorable spot-type heat detector be functionally tested?
- 5006Single and multiple station smoke alarms must be replaced no later than how long after the date of manufacture?
- 5007Before testing a monitored fire alarm system, whom must the technician notify?
- 5008After a software change on a fire alarm system, what portion of initiating devices not directly affected must be tested?
- 5009How long must inspection and test records be kept?
- 5010Under NFPA 101, a required fire alarm system will be out of service for more than 4 hours in a 24 hour period. What is required?
- 5011What document is prepared at acceptance to record the installed system details, and is kept for the life of the system?
- 5012What is the frequency for the visual inspection of fire alarm control units in a monitored system?
- 5013How often must a sealed lead acid fire alarm battery receive its load voltage and charger tests?
- 5014During an annual test, a duct smoke detector does not alarm with test smoke. What should the technician check first?
- 5015What is the required frequency for testing a vane type waterflow switch with flow through the inspector's test connection?
- 5016During an acceptance test, which items should the technician verify for every notification appliance?
- 5017Which personnel qualification does NFPA 72 accept for inspection, testing and maintenance of fire alarm systems?
- 5018A detector repeatedly causes nuisance alarms near a kitchen entrance. What is the most appropriate corrective action?
- 5019How often must manual fire alarm boxes be functionally tested?
- 5020How often must audible and visible notification appliances be functionally tested?
- 5021During the annual test of a monitored system, what must be verified with the supervising station?
- 5022A smoke detector shows a dirty or maintenance alert. What is the correct service approach?
- 5023A Class B initiating circuit with a 4.7 kilohm end of line resistor is disconnected from the panel and measured. The meter shows OL (infinite). What does this indicate?
Job Site Safety
- 6001A straight or extension ladder has a working length of 20 ft to the support point. How far should its base be from the wall?
- 6002When a portable ladder is used to reach an upper landing such as a roof, how far must the side rails extend above the landing?
- 6003On a construction site, at what height above a lower level does OSHA generally require fall protection for workers on an unprotected side or edge?
- 6004While installing a detector from a stepladder, which practice violates OSHA ladder rules?
- 6005Which section of a Safety Data Sheet describes exposure controls and the required personal protective equipment?
- 6006Before working on the 120 V branch circuit that feeds a fire alarm control unit, what should the technician do?
- 6007A technician must enter a tank vault classified as a permit required confined space to service a device. What is required?
- 6008Eye protection used while drilling overhead for device mounting should meet which standard?
- 6009On a construction site, what protection does OSHA require for 120 V, 15 and 20 A temporary receptacles used by workers?
- 6010Head protection worn on a construction site must meet which standard?
- 6011Above what 8 hour time weighted average noise level must OSHA's construction noise controls or hearing protection be used?
- 6012At what height does a scaffold platform require fall protection such as guardrails?
- 6013What does OSHA require of a worker climbing up or down a ladder?
- 6014A technician must work near exposed energized electrical equipment from a portable ladder. Which ladder is required?
- 6015An extension cord on the job has frayed insulation. What should be done?
- 6016While drilling for a detector in an older building, you find ceiling material that may contain asbestos. What is the right action?